List of Dell PowerEdge Servers
Dell PowerEdge is a server line by Dell, following the naming convention for other Dell products: the PowerVault (data storage) and the PowerConnect (data transfer & switches).
Below is an overview of current and former servers within Dell's PowerEdge product line. Different models are or were available as towers, 19-inch racks or blades. In the current naming scheme, towers are designated by T, racks by R, and blades by M (for modular).[1] The 19″ rack-servers come in different physical heights expressed in rack units or U. Most modern servers are either 1U or 2U high while in the past the 4U was more common.
Model naming
Over the years, many different types of PowerEdge servers have been introduced and there was wide variety of product and family codes used within the PowerEdge name.
Itanium servers
The Dell Itanium-based servers were introduced before this new naming-convention was introduced and were only available as rack servers.
New naming conventions
- Three digits
Since the introduction of the Generation 10 servers in 2007 Dell has adopted a standardized method for naming their servers; the name of each server is now represented by a letter followed by 3 digits.[2] The letter indicates the type of server: R (for Rack-mountable) indicates a 19″ rack-mountable server, M (for Modular) indicates a blade server, whilst T (for Tower) indicates a stand-alone server.[3]
This letter is then followed by three digits.
- The first digit refers to the number of sockets in the system: 1 to 3 for one socket, 4 to 7 for two sockets, and 8 or 9 for four sockets.
- The middle digit refers to the generation: 0 for Generation 10, 1 for Generation 11, and so on.
- The third digit indicates the make of the CPU: 0 for Intel or 5 for AMD.
For example: The Dell PowerEdge M610 is a two-socket blade server of the 11th generation using an Intel CPU. Whereas the R605 is a two-socket, 10th generation AMD-based rack-server.
- Four digits
For four-digit naming convention:
- The first digit after the letter indicates the class of the system, with 1–5 defaulting to iDRAC Basic and 6–9 defaulting to iDRAC Express.
- The second digit indicates the generation, with 0 for 10th generation, 1 for 11th generation and so on.
- The third digit indicates the number of CPU sockets, 1 for one socket and 2 for two sockets.
- The fourth digit indicates the make of the CPU, 0 for Intel and 5 for AMD.
For example: The Dell PowerEdge R6415 model is a rack, mid-range, 14th generation, single CPU socket system with AMD Processor.
Blade servers
Since Generation 10 there are models for the M1000e enclosure. The blade-servers in Generation 8 and Generation 9 are using another enclosure that is not compatible with the current M1000e system. In form-factor there are two models: half-height and full-height. In an enclosure you can fit 8 full or 16 half-height blades (or a mix). Each server has two or four on-board NIC's and two additional Mezzanine card-slots for additional I/O options: 1 Gb or 10 Gb Ethernet cards, Fibre Channel HBA's or InfiniBand slots. Apart from USB connectors a blade-server doesn't offer direct connections: all I/O goes via the midplane of the enclosure.
Early systems
Early systems (SP, XE, EL, XL lines) | |||||||||
---|---|---|---|---|---|---|---|---|---|
Model | Chassis | Year | Chipset | CPU (No. & Socket) | CPU (Type) | RAM (Max) | RAM (Type) | Drive bays | Comments |
SP 433 | Tower | 1 | Intel 80486 33 MHz (P4) | EISA/PCI | |||||
SP 450 | Tower | 1 | Intel 80486DX2 50 MHz (P24) | EISA/PCI | |||||
SP 466 | Tower | 1 | Intel 80486DX2 66 MHz (P24) | EISA/PCI | |||||
SP 560 | Tower | 1 Socket 4 | Pentium 60 60 MHz (P5) | EISA/PCI | |||||
SP 566 | Tower | 1 Socket 4 | Pentium 66 66 MHz (P5) | EISA/PCI | |||||
SP 575-2 | Tower | 1995[4] | 1,2 Socket 5 | Pentium 75 75 MHz (P54C) | EISA/PCI | ||||
SP 590 | Tower | 1994[5] | 1 Socket 5 | Pentium 90 90 MHz (P54C) | 192 MB | SIMM | 8 | EISA/PCI | |
SP 590-2 | Tower | 1,2 Socket 5 | Pentium 90 90 MHz (P54C) | EISA/PCI | |||||
SP 5100[6] | Tower | 1,2 | Pentium 100 100 MHz (P54C) | EISA/PCI | |||||
SP 5100-2[6] | Tower | 1,2 | Pentium 100 100 MHz (P54C) | EISA/PCI | |||||
SP 5133[6] | Tower | 1,2 | Pentium 133 133 MHz (P54CS) | EISA/PCI | |||||
SP 5133-2[6] | Tower | 1,2 | Pentium 133 133 MHz (P54CS) | EISA/PCI | |||||
SP 5166[6] | Tower | 1,2 | Pentium 166 166 MHz (P54CS) | EISA/PCI | |||||
SP 5166-2[6] | Tower | 1,2 | Pentium 166 166 MHz (P54CS) | EISA/PCI | |||||
XE 433 | Tower | 1 | Intel 80486 33 MHz (P4) | EISA/PCI | |||||
XE 450 | Tower | 1 | Intel 80486DX2 50 MHz (P24) | EISA/PCI | |||||
XE 466 | Tower | 1 | Intel 80486DX2 66 MHz (P24) | EISA/PCI | |||||
XE 560 | Tower | 1 Socket 4 | Pentium 60 60 MHz (P5) | EISA/PCI | |||||
XE 566 | Tower | 1 Socket 4 | Pentium 66 66 MHz (P5) | EISA/PCI | |||||
XE 575-2 | Tower | 1,2 Socket 5 | Pentium 75 75 MHz (P54C) | EISA/PCI | |||||
XE 590 | Tower | 1,2 Socket 5 | Pentium 90 90 MHz (P54C) | EISA/PCI | |||||
XE 590-2 | Tower | 1,2 Socket 5 | Pentium 90 90 MHz (P54C) | EISA/PCI | |||||
XE 5100 | Tower | 1,2 | Pentium 100 100 MHz (P54C) | EISA/PCI | |||||
XE 5100-2 | Tower | 1,2 | Pentium 100 100 MHz (P54C) | EISA/PCI | |||||
XE 5133 | Tower | 1,2 | Pentium 133 133 MHz (P54CS) | EISA/PCI | |||||
XE 5133-2 | Tower | 1,2 | Pentium 133 133 MHz (P54CS) | EISA/PCI | |||||
XE 5166 | Tower | 1,2 | Pentium 166 166 MHz (P54CS) | EISA/PCI | |||||
XE 5166-2 | Tower | 1,2 | Pentium 166 166 MHz (P54CS) | EISA/PCI | |||||
EL 575 | Tower | Pentium 75 75 MHz (P54C) | ISA/PCI | ||||||
EL 590 | Tower | Pentium 90 90 MHz (P54C) | ISA/PCI | ||||||
EL 5100 | Tower | Pentium 100 100 MHz (P54C) | ISA/PCI | ||||||
EL 5120 | Tower | Pentium 120 120 MHz (P54CQS) | ISA/PCI | ||||||
EL 5133 | Tower | Pentium 133 133 MHz (P54CS) | ISA/PCI | ||||||
Web Server | Tower | 1995[7] | Pentium 133 133 MHz (P54CS) | ISA/PCI, based on quad processor EL[7] | |||||
XL 5133 | Tower | 1-4 (single, quad capable) | Pentium 133 133 MHz (P54CS) | EISA/PCI | |||||
XL 5133-2 | Tower | 1-4 (dual, quad capable) | Pentium 133 133 MHz (P54CS) | EISA/PCI | |||||
XL 5133-4[8] | Tower | 1-4 (quad) | Pentium 133 133 MHz (P54CS) | EISA/PCI | |||||
XL 5166 | Tower | 1-4 (single, quad capable) | Pentium 166 166 MHz (P54CS) | EISA/PCI | |||||
XL 5166-2 | Tower | 1-4 (dual, quad capable) | Pentium 166 166 MHz (P54CS) | EISA/PCI | |||||
XL 5166-4 | Tower | 1-4 (quad) | Pentium 166 166 MHz (P54CS) | EISA/PCI |
Generation 1
Model | Chassis | Year | Chipset | CPU (No. & Socket) | CPU (Type) | RAM (Max) | RAM (Type) | Drive bays | Comments |
---|---|---|---|---|---|---|---|---|---|
2100[9] | Tower | 1996 | Intel 440FX | 1 Socket 8 | Pentium Pro 180 MHz or 200 MHz | 256 MB | 4, 168-pin DIMM | ||
4100[10] | Tower | 2 Socket 8 | Pentium Pro 180 MHz or 200 MHz | 1 GB | 8, 168-pin DIMM | ||||
6100[11] | Tower | 4 Socket 8 | Pentium Pro 200 MHz | 2 GB | 16, 72-pin |
Generation 2
Model | Chassis | Year | Chipset | CPU (No. & Socket) | CPU (Type) | RAM (Max) | RAM (Type) | Drive bays | Comments |
---|---|---|---|---|---|---|---|---|---|
2200[12] | Tower | 2 | Pentium II, 233 - 333 MHz | 512 MB | 4, ECC | 3 full size SCSI drives (screw in) | |||
4200[13] | Tower | Intel 440FX | 2 | Pentium II 233, 266, 300, or 333 MHz | 512 MB | 8, 168-pin EDO DIMM |
Generation 3
Model | Chassis | Year | Chipset | CPU (No. & Socket) | CPU (Type) | RAM (Max) | RAM (Type) | Drive bays | Comments |
---|---|---|---|---|---|---|---|---|---|
350[14] | 1U Rack | circa 2001 | Intel 440BX | Pentium III 650Mhz-1.0Ghz or Celeron 600+ |
1 GB | 4, SDRAM unbuffered and registered PC-100 | (2) int. 3.5 ATA-100 (1) slim 3.5″ floppy (1) slim CD-ROM |
(2) Intel 82559 10/100 125 W 898 BTU/hr (max) | |
1300[15] | Tower | Intel 440BX | 1 | Pentium II at 350, 400, or 450 MHz | 1 GB | unbuffered, 72-bit SDRAM or registered, 72-bit SDRAM | |||
2300[16] | Tower | 1998 | Intel 440BX | 2 | Pentium II 333, 350, 400, 450 MHz | 1 GB | 4, unregistered PC-100 SDRAM | 6 Ultra2 SCSI HDD bays | |
4300[17] | 7U Rack | Intel 440GX | 2 | Pentium II 350, 400, or 450 MHz | 1 GB | 4, 168-pin unbuffered DIMMs or registered DIMMs | 8 SCSI bays | ||
4350[18] | Rack | Intel 440GX | 2 | Pentium II 350, 400, or 450 MHz | 2 GB | ||||
6300[19] | Tower | 4 | Pentium II Xeon | 4 GB | 4, registered EDO DIMM | 6 Ultra2 SCSI HDD bays | |||
6350[20] | 4U Rack | 4 | Pentium II Xeon at 400 MHz | 4 GB | 16, registered EDO DIMM | 3 HDD bays |
Generation 4
Model | Chassis | Year | Chipset | CPU (No. & Socket) | CPU (Type) | RAM (Max) | RAM (Type) | Drive bays | Comments |
---|---|---|---|---|---|---|---|---|---|
2400[21] | Tower | 2000[22] | 2 | Pentium III 500 MHz minimum | 2 GB | 4, registered PC-133 SDRAM | 6 Ultra2 SCSI HDD bays | ||
2450[23] | 2U Rack | 2001 | 2 | Pentium III 600 MHz minimum | 2 GB | 168-pin registered SDRAM 133-MHz | |||
4400[24] | 7U Rack or Tower |
2 | Pentium III Xeon, 600 MHz minimum | 4 GB | registered PC133 SDRAM | Up to 10 internal SCSI bays | Introduced circa 1999 | ||
6400[25] | Tower | 4 | Pentium III Xeon, 550 MHz minimum | 8 GB | 16, registered PC-133 SDRAM | 6 or 8 Ultra3 SCSI drives | Introduced circa 1999 | ||
6450[26] | 4U Rack | 4 | Pentium III Xeon 550 MHz | 8 GB | 16, registered PC-133 SDRAM | 4 internal SCSI bays | Introduced circa 1999 | ||
8450[27] | Rack | 2000[28] | 8 | Pentium III Xeon 500 MHz | 32 GB | 168-pin SDRAM 100 MHz |
Generation 5
Model | Chassis | Year | Chipset | CPU (No. & Socket) | CPU (Type) | RAM (Max) | RAM (Type) | Drive bays | Comments |
---|---|---|---|---|---|---|---|---|---|
1550[29] | 1U Rack | 2001[30] | ServerWorks HE-SL | 2 | Pentium III (933 MHz-1.4 GHz) | 4, registered PC-133 SDRAM | 3 hot-swappable Ultra3 SCSI HDD bays | ||
2500[31] | Tower or 5U Rack | 2 | Pentium III 933 MHz minimum | 4 GB | 6, ECC registered PC-133 SDRAM | 6 hot-swappable Ultra3 SCSI HDD bays, splittable | |||
2550[32] | 2U Rack | 2 | Pentium III 933 MHz minimum | 4 GB | registered PC133 SDRAM | 5 internal SCSI bays | Introduced circa 2001 |
Itanium
The Itanium line was a separate 'generation' from the traditional server line, but roughly falls between generations 5 and 6.
Itanium systems (3250, 7150, 7250 models (2001-2004)) | |||||||||
---|---|---|---|---|---|---|---|---|---|
Model | Chassis | Year | Chipset | CPU (No. & Socket) | CPU (Type) | RAM (Max) | RAM (Type) | Drive bays | Comments |
3250[33] | 2U Rack | 2003 | Intel E8870 | 2 PAC611 | Intel Itanium 2 1.5 GHz, 1.3 GHz, 1.4 GHz, 1.0 GHz | 16 GB | DDR SDRAM | 2 x 1″ SCSI drives | |
7150[34] | 7U Rack | 2001[35] | 4 PAC418 | Intel Itanium minimum 733 MHz | 64 GB | PC100 memory | 4 hotplug SCSI bays | ||
7250[36] | Rack | 2004 | Intel E8870 | 4 PAC611 | Intel Itanium 2 | 32 GB | DDR ECC memory | 3 hotplug SCSI bays |
Generation 6
Model | Chassis | Year | Chipset | CPU (No. & Socket) | CPU (Type) | RAM (Max) | RAM (Type) | Drive bays | Comments |
---|---|---|---|---|---|---|---|---|---|
650[37] | 1U Rack | 2003 | 1 | Pentium 4 up to 3.06 GHz or Celeron up to 1.8 GHz | 3 GB | DDR | 2× IDE or SCSI | ||
1650[38] | 1U Rack | 2002[39] | 2 | Pentium III 1.13 GHz+ | 4 GB | 4, ECC SDRAM 133 | |||
1655 MC[40] | 3U Blade | 2004 | ServerWorks ServerSet LE3.0 | 2 (per Blade) | Pentium III at 1.4 GHz | 2 GB (per Blade) | 4, ECC SDRAM 133 | Houses up to 6 blades | |
2600[41] | Tower or 5U Rack | 2004 | Intel E7501 | 2 Socket 604 | Xeon III at 2.4 GHz, 2.8 GHz, 3.06 GHz and 3.2 GHz | 12 GB | 6, ECC DDR 266 | 6 HDD bays (SCSI) | |
2650[42] | 2U Rack | 2004 | ServerWorks GC-LE | 2 Socket 603 | Xeon at 2.0 GHz, 2.4 GHz, 2.8 GHz, 3.06 GHz and 3.2 GHz | 12 GB | 6, ECC DDR 266 | 5 HDD bays (SCSI) | |
4600[43] | Tower or 6U Rack | 2003 | ServerWorks GC-HE | 2 Socket 603 | Xeon at 2.4 GHz, 2.6 GHz, 2.8 GHz to 3.0 GHz | 24 GB | ECC DDR | 2 RAM riser cards | |
6600[44] | Tower or 7U Rack | 2004 | ServerWorks GC-HE | 4 | Xeon MP at 2.0 GHz, 2.2 GHz, 2.7 GHz or 3.0 GHz | 32 GB | ECC DDR 266 | 8 SCSI | 4 RAM riser cards |
6650[44] | 4U Rack | 2004 | ServerWorks GC-HE | 4 | Xeon MP at 1.4 GHz, 2.0 GHz, 2.2 GHz, 2.7 GHz or 3.0 GHz | 32 GB | ECC DDR 266 | 5 SCSI | 4 RAM riser cards |
Generation 7
Model | Chassis | Year | Chipset | CPU (No. & Socket) | CPU (Type) | RAM (Max) | RAM (Type) | Drive bays | Comments |
---|---|---|---|---|---|---|---|---|---|
700[45] | Tower | 2004 | Intel E7210 | 1 Socket 478 | Pentium 4(up to 3.2 GHz/800 MHz) or Celeron (2.4 GHz) | 4 GB | DDR 400 | 4 HDD bays | |
750[46] | 1U Rack | 2005 | Intel E7210 | 1 Socket 478 | Pentium 4(up to 3.4 GHz/800 MHz) or Celeron (2.4 GHz) | 4 GB | DDR 400 | 2 SCSI or SATA | |
1750[47] | 1U Rack | 2004 | ServerWorks GC LE | 2 Socket 604 | Xeon up to 3.2 GHz | 8 GB | 4, DDR 266 | 3 HDD bays (SCSI) |
Generation 8
Model | Chassis | Year | Chipset | CPU (No. & Socket) | CPU (Type) | RAM (Max) | RAM (Type) | Drive bays | Comments |
---|---|---|---|---|---|---|---|---|---|
800[48] | Tower | 2005 | Intel E7221 | 1 LGA 775 | Pentium 4 up to 3.8 GHz or Celeron up to 2.53 GHz | 4 GB | 4, ECC DDR2 400/533 | 4 × 1″ SCSI or SATA | |
830[49] | Tower | 2005 | Intel E7230 | 1 LGA 775 | Pentium D up to 3.2 GHz or Pentium 4 up to 3.6 GHz or Celeron D 2.53 GHz | 8 GB | 4, ECC DDR2 533-667 | 4 × HDD bays | |
840 (Gen I, II) [50][51] |
Tower | 2006 | Intel 3000 | 1 LGA 775 | Xeon X3200 (Gen II only), Xeon 3000, Pentium or Celeron | 8 GB | 4, ECC DDR2 533-667 | 2 × 5.25″ ext. 1 × 3.5″ ext. 4 × 3.5″ int. 4 SATA 2 IDE |
|
1800[52] | Tower or 5U Rack | Intel E7520 | 2 Socket 604 | Xeon, 800 MHz FSB | 12 GB | 6, ECC DDR2 | 6 × HDD bays (SCSI) | ||
1850[53] | 1U Rack | 2005 | Intel E7520 | 2 Socket 604 | Xeon, 800 MHz FSB | 16 GB | 6, ECC DDR2 400 | 2 × HDD bays (SCSI) | |
1855[54] | Blade | 2005 | Intel E7520 | 2 Socket 604 | Xeon, 800 MHz FSB | 12 GB | 6, ECC DDR2 | 2 × HDD bays per blade(SCSI) | Uses same blade chassis as 1955, up to 10 blades |
2800[55] | Tower or 5U Rack | 2005 | Intel E7520 | 2 Socket 604 | Xeon Single or Dual-core | 16 GB | 6, DDR2 400 | 8 to 10 HDD bays (SCSI) | |
2850[56] | 2U Rack | 2005 | Intel E7520 | 2 Socket 604 | Xeon up to 3.8 GHz or Dual-core Xeon at 2.8 GHz | 16 GB | 6, DDR2 400 | 6 × HDD bays (SCSI) | |
6800[57] | Tower | 2006 | Intel 8501 | 4 Socket 604 | Xeon 7100 | 64 GB | 16*, ECC DDR2 | 10 Hotplug SCSI bays | rAM slots only with daughterboard |
6850[58] | 4U Rack | 2006 | Intel 8501 | 4 Socket 604 | Xeon 7100 | 64 GB | 16*, ECC DDR2 | 5 Hotplug SCSI bays | rAM slots only with daughterboard |
Generation 9
Model | Chassis | Year | Chipset | CPU Sockets | CPU | RAM (Max) | RAM (Type) | Drive bays | Comments |
---|---|---|---|---|---|---|---|---|---|
850[59] | 1U Rack | 2005 | Intel E7230 | 1 LGA 775 | Intel Pentium 4 (up to 3.8 GHz) or Celeron (2.53 GHz) or Pentium D dual-core (up to 3.2 GHz) | 8 GB | 4, ECC DDR2 533/667 MHz | 2 × 3.5″ SATA or SCSI | |
860 (Gen I, II) [60][61] |
1U Rack | 2006 | Intel 3000 | 1 LGA 775 | Celeron D, Pentium D 925, Celeron 430/440, Pentium Dual-Core E2160, Core 2 Duo E4400, Xeon 3000, Xeon 3200 | 8 GB | 4, ECC DDR2 533/667 MHz | 2 × 3.5″ SATA or SAS and 1 × slim optical | The PE 850 and 860 share chassis with the R200, and other than name badge are visually identical. |
1900[62] | Tower | 2006 | Intel 5000P | 2 LGA 771 | Xeon 5000, 5100 or 5300 | 16 GB | 8, DDR2 533/667 MHz FB-DIMM | 6 × 3.5″ SAS/SATA and 1 × Peripheral bay and 1 × 3.5″ floppy | This model replaces the 1800. Peripheral bay can hold 2 × 5.25″ devices |
1950 (Gen I, II, III) [63] |
1U Rack | 2006 | Intel 5000X | 2 LGA 771 | GI: Xeon 5000, 5100 GII: Xeon 5000, 5100, 5300 GIII: Xeon 5000, 5100, 5200, 5300, 5400 |
GI & GII: 32 GB; GIII: 64 GB | GI & GII: 8, ECC DDR2 533/667 MHz FB-DIMM GIII: 8, ECC DDR2 667 MHz FB-DIMM |
2 × 3.5″ SAS/SATA or 4 × 2.5″ SAS and 1 × slim optical | |
1955[64] | Blade | 2006 | Intel 5000P | 2 LGA 771 | Xeon 5000, 5100 or 5300 | 32 GB | 8, ECC DDR2 FB-DIMM | 2 × 2.5″ SAS/SATA | Uses same blade chassis as 1855. Up to 10 blades |
2900 (Gen I, II, III) [65] |
Tower or 5U | 2006 | Intel 5000X | 2 LGA 771 | Xeon 5000, 5100, 5300 or 5400 | 48 GB | 12, ECC DDR2 533/667 MHz FB-DIMM | 8 × 3.5″ SAS/SATA and 1 × Flexbay and 1 × Peripheral bay and 1 × 3.5″ floppy | Flexbay can hold 2 × 3.5″ HDD. Peripheral bay can hold 2 × 5.25″ devices |
2950 (Gen I, II, III) [66][67] |
2U Rack | 2006 | Intel 5000X | 2 LGA 771 | GI: Xeon 5000, 5100 GII: Xeon 5000, 5100, 5300 GIII: Xeon 5000, 5100, 5200, 5300, 5400 |
GI: 32 GB; GII[68] & GIII: 64 GB | GI & GII: 8, ECC DDR2 533/667 MHz FB-DIMM GIII: 8, ECC DDR2 667 MHz FB-DIMM |
8 × 2.5″ SAS and 1 × Peripheral bay or 4 × 3.5″ SAS/SATA and 1 × Peripheral bay or 6 × 3.5″ SAS/SATA and 1 × slim optical | All configurations include 1 × slim optical drive. Peripheral bay options: Floppy Drive, DAT72 Tape Drive |
2970[69] | 2U Rack | 2007[70] | Broadcom HT-2100 and HT-1000 | 2 Socket F | Opteron 2200 | 32 GB | 8, ECC DDR2 667 MHz | 8 × 2.5″ SAS/SATA II or 6 × 3.5″ SAS/SATA and 1 × Peripheral bay and 1 × slim optical | Peripheral bay options; Floppy Drive, PowerVault 100T Tape Drive |
6950[71] | 4U Rack | 2006[72] | Broadcom HT-2100 and HT-1000 | 4 Socket F | Opteron 8200 or 8300 | 64 GB | 16, ECC DDR2 667 MHz | 5 × 3.5″ SAS and 1 × slim optical |
Generation 10
Model | Chassis | Year | Chipset | CPU (No. & Socket) | CPU (Type) | RAM (Max) | RAM (Type) | Drive bays | Comments |
---|---|---|---|---|---|---|---|---|---|
T100[73] | Tower | 2008[74] | Intel 3200 | 1 LGA 775 | Xeon 3000, Core 2 Duo 7000, Pentium 2000, Celeron 1200 or Celeron 400 | 8 GB | 4, ECC DDR2 677-800 | 2 × 3.5″ SATA or SAS and 2 × 5.25″ | |
T105[75] | Tower | 2008 | nVidia CK8-04 Pro | 1 Socket AM2 | Opteron 1200, Opteron 1300, Sempron LE1250 | 8 GB | 4, ECC DDR2 677-800 | 2 × 3.5″ SATA or SAS and 2 × 5.25" | |
R200[76] | 1U Rack | 2010 | Intel 3200 | 1 LGA 775 | Xeon 3000, Core 2 Duo, Celeron | 8 GB | 4, ECC DDR2 667-800 SDRAM[lower-alpha 1] | 2 × 3.5″ non-hot-swap SATA or SAS and 1 × 5.25″ removable CD/DVD | |
T300[77] | Tower | 2007 | Intel 5100 | 1 LGA 771 | Xeon 5000, Xeon 3000, Core 2 Duo, Celeron | 24 GB | 6, ECC DDR2 667 | 4 × 3.5″ SATA or SAS | |
R300[78] | 1U Rack | Intel 3400 | 1 LGA 771 | Xeon 5000, Xeon 3000, Core 2 Duo, Celeron | 24 GB | 6, ECC DDR2 667 | 2 × 3.5″ | ||
M600[79] | Blade | Intel 5000P | 2 LGA 771 | Xeon 5000 | 64 GB | 8, ECC DDR2 667 | Fits in the M1000E chassis | ||
T605[80] | Tower | 2008[81] | Broadcom HT2100 and HT1000 | 2 Socket F | Opteron 2000 | 32 GB | 8, ECC DDR2 | 4 × 3.5″ and 1 × 5.25″ | |
M605[82] | Blade | NVIDIA MCP55 | 2 Socket F | Opteron 2000, 2200 or 2300 | 64 GB | 8, ECC DDR2 800 | 2 × 2.5″ SAS or SATA | Fits in the M1000E chassis | |
R805[83] | 2U Rack | 2008[84] | NVIDIA MCP55Pro + IO-55 | 2 Socket F | Opteron 2400 | 128 GB | 16, ECC DDR2 | 2 × 2.5″ and 1 × slim optical | |
M805[85] | Blade | NVIDIA MCP55 | Opteron 2000 | 128 GB | 16, ECC DDR2 667-800 | 2 × 2.5″ SAS or SSD | Fits in the M1000E chassis | ||
R900[86] | 4U Rack | Intel 7300 | 4 Socket 604 | Xeon 7200, 7300 or 7400 | 256 GB | 32, FBD DDR2 667-1333 | 5 × 3.5″ SAS or 8 × 2.5″ SAS | ||
R905[87] | 4U Rack | Broadcom HT-2100 and HT-1100 | 4 | Opteron 8000 | 256 GB | 32, ECC DDR2 | 8 × 2.5″ or 5 × 3.5″ | EOL : 7/23/2015 | |
M905[88] | Blade | NVIDIA MCP55 | 4 | Opteron 8000 | 192 GB | 24, ECC DDR2 667–800 | 2 × 2.5″ SAS or SSD | Fits in the M1000E chassis |
Generation 11
Released by Dell in 2010
Model | Chassis | Year | Chipset | CPU
(No. & Socket) |
CPU (Type) | RAM (Max) | RAM (Type) | Drive bays | Comments |
---|---|---|---|---|---|---|---|---|---|
T110[89] | Tower | Intel 3420 | 1 LGA 1156 | Xeon 3400, Celeron G1101, Pentium G6950, Core i3-530 or i3-540 | 16 GB | 4, U-DIMMs ECC DDR3 1066-1333 | 4 × 3.5″ SAS or SATA | ||
T110 II[90] | Tower | 2011 | Intel C202 | 1 LGA 1155 | Xeon E3-1200 or E3-1200 v2, Celeron G400 / G500, Pentium G600 / G800 | 32 GB | 4, U-DIMMs ECC DDR3 1066-1600 | 4 × 3.5″ or 6 × 2.5″ SAS or SATA | |
R210[91] | 1U Rack | Intel 3420 | 1 LGA 1156 | Xeon 3400, Celeron G1101, Pentium G6950 or Core i3-500 | 16 GB | 4, U-DIMMs ECC DDR3 1066-1333 | 2 × 2.5″ or 2 × 3.5″ SAS, SATA or SSD | ||
R210 II[92] | 1U Rack | 2011 | Intel C202 | 1 LGA 1155 | Xeon E3-1200 or E3-1200 v2, Celeron G400 / G500, Pentium G600 / G800 | 32 GB | 4, U-DIMMs ECC DDR3 1066-1600 | 4 × 2.5″ or 2 × 3.5″ SAS, SATA or SSD | |
T310[93] | Tower | Intel 3400 | 1 LGA 1156 | Xeon 3400, Celeron G1101, Pentium G6950 or Core i3-500 | 32 GB | 6, R-DIMMs or 4, U-DIMMs, DDR3 800-1333 | 4 × 3.5″ SAS or SATA | ||
R310[94] | 1U Rack | Intel 3420 | 1 LGA 1156 | Xeon 3400, Celeron G1101, Pentium G6950, Core i3-530 or i3-540 | 32 GB | 6, 1066–1333 | 4 × 3.5″ or 4 × 2.5” SAS or SATA | ||
T410[95] | Tower | 2009[96] | Intel 5500 | 2 LGA 1366 | Xeon 5500 or 5600 | 128 GB | 8, DDR3 800-1333 | 6 × 3.5″ and 2 × 5.25″ SSD, SAS or SATA | |
R410[97] | 1U Rack | 2009[98] | Intel 5500 | 2 LGA 1366 | Xeon 5500 or 5600 | 64 GB | 8, DDR3 800-1333 | 4 × 3.5″ or 4 × 2.5″ | |
R415[99] | 1U Rack | AMD SR5670 & SP5100 | 2 C32 | Opteron 4100, 4200 or 4300[100] | 256 GB[100] | 8, DDR3 1066/1333 | 4 × 2.5″ or 4 × 3.5″ SAS or SATA | ||
R510[101] | 2U Rack | Intel 5500 | 2 LGA 1366 | Xeon 5500 or 5600 | 128 GB | 8, DDR3 800-1333 | 4 × 3.5″ or 8 × 2.5″/3.5″ or 12 × 2.5″/3.5″ and 2 × 2.5″ internal | ||
R515[102] | 2U Rack | 2010 | AMD SR5670 & SP5100 | 2 C32 | rev I: Opteron 4100; Rev II: 4100 or 4200 | Opteron 4100: 128 GB; Opteron 4200: 256 GB | 8, DDR3 1333-1600 | 12 × 2.5″ or 8 × 3.5″ | |
T610 (Gen I, II) [103] |
Tower or 5U Rack | Intel 5520 | 2 LGA 1366 | Xeon 5500 or 5600 | 192 GB | 12, RDIMM or UDIMM DDR3 800-1333 | Up to 8 × 3.5″/2.5″ SSD, SAS or SATA | ||
R610 (Gen I, II) [104] |
1U Rack | Intel 5520 | 2 LGA 1366 | Xeon 5500 or 5600 | 192 GB | 12, DDR3 800-1333 | 6 × 2.5″ SAS or SSD | ||
M610 (Gen I, II) [105] |
Blade | Intel 5520 | 2 LGA 1366 | Xeon 5500 or 5600 | 192 GB | 12, ECC DDR3 | 2 × 2.5″ SAS/SSD | Fits in the M1000E chassis | |
T710 (Gen I, II) [106] |
Tower or 5U Rack | Intel 5520 | 2 LGA 1366 | Xeon 5500 or 5600 | 192 GB | 18, DDR3 800–1333 | 16 × 2.5″ or 8 × 3.5″ | ||
R710 (Gen I, II) [107] |
2U Rack | 2009[108] | Intel 5520 | 2 LGA 1366 | Xeon 5500 or 5600 | 288 GB | 18, DDR3 800-1333 | 8 × 2.5″ or 6 × 3.5″ | Gen I: No 130W CPUs [109] |
R715[110] | 2U Rack | 2010[111] | AMD SR5650, SR5670, SP5100 | 2 G34 | Opteron 6100 or 6200 | 256 GB | 16, DDR3 800–1600 | 8 × 2.5″ or 6 × 3.5″ | |
M710 (Gen I, II) [112] |
Blade | Intel 5520 | 2 LGA 1366 | Xeon 5500 or 5600 | 192 GB | 18, DDR3 | 4 × 2.5″ SAS or SSD | Fits in the M1000E chassis | |
R810 [113][114] | 2U Rack | Intel 7500 | 4 LGA 1567 | Xeon 6500 or 7500 | 1 TB[115] | 32, DDR3 1066 | 6 × 2.5″ SAS, SATA or SATA SSD | ||
R815 [116][117] | 2U Rack | AMD SR5650, SR5670, SP5100 | 4 G34 | Opteron 6100 | 512 GB | 32, DDR3 1333 | 6 × 2.5″ SAS, SATA or SATA SSD | ||
R910[118] | 4U Rack | Intel 7500 | 4 LGA 1567 | Xeon 7500 or E7-4/8800 | 2 TB[119] | 64, DDR3 1066 | 16 × 2.5″ SAS or SSD | R910 servers using Xeon 7500 CPUs are limited to 1 TB of memory since 32GB DIMMs are not supported[120] | |
M910[121] | Blade | Intel 7500 | 4 LGA 1567 | Xeon 6500 or 7500 | 512 GB | 32, ECC DDR3 | 2 × 2.5″ SAS or SSD | Fits in the M1000E chassis | |
C1100[122] | 1U Rack | Intel 5500 | 2 LGA 1366 | Xeon 5500 or 5600 | 192 GB | 18, ECC DDR3 1066-1333 | 10 × 2.5″ or 4 × 3.5″ | ||
C2100[123] | 2U Rack | Intel 5500 | 2 LGA 1366 | Xeon 5500 or 5600 | 192 GB | 18, ECC DDR3 1066-1333 | 12 × 3.5″ and 2 × 2.5″ internal SATA or SSD | ||
C6100[124] | 2U Rack | Intel 5520 | 8 LGA 1366 | Xeon 5500 or 5600 | 768 GB | 48, DDR3 1066-1333 | 24 × 2.5″ or 12 × 3.5″ |
Generation 12
In March 2012 Dell introduced their 12th generation servers based on Intel Xeon. There are two basic lines: 620 and 720.[125] On the 720 line, Dell currently offers two rack-model servers: the Poweredge R720[126] and the R720XD[127] — where the latter offers the option to extend the system to up to 26 internal disks.
The Poweredge 620 series offer models for rack, tower and a ½ height blade-server M620.[125] A ½ height blade means that you can fit up to 16 of those servers in one M1000e enclosure. The M520 and M620 can also be used in the new PowerEdge VRTX system. The new M420 is 1/4 height, so 32 fit in a M1000e chassis but does require a special full height holder that fits 4 M420's in one full-height (=double) slot.
For the Generation 12 server-line the out of band server-management system iDRAC received a new version: iDRAC 7. iDRAC allows you to access the server-console via a separate ethernet connection allowing you to get access to the server even when there is no (working) operating system or (normal) network connection available. It offers more or less the same functionality as a network-enabled KVM switch, but with some additional options.
An overview of the offered servers as per July 2012[125]
Model | Chassis | Year | Chipset | CPU (No. & Socket) | CPU (Type) | RAM (Max) |
RAM (Type) | Internal Storage (Max) |
Drive bays | PCI(e) slots | On board network |
---|---|---|---|---|---|---|---|---|---|---|---|
T620[128] | Tower rackable, 5U |
2012 | C600 | 2 LGA 2011 | Xeon E5-2600 | 768 GB | 24, DIMM DDR3, 1600Mhz |
36 TB | 8 × 3.5″ + 4 × PCIe SSD or 12 × 3.5″ or 16 × 2.5″ + 4 × PCIe SSD or 32 × 2.5″ |
7: 4 - x16 FH/FL, 2 - x8 FH/FL, 1 - x8 (x4bw) FH/FL | Broadcom or Intel Quad 1 Gb or Dual 10 Gb |
R220[129] | 1U Rack | C222 | 1 LGA 1150 | Xeon E3-1200 v3 | 32 GB | 4, DIMM DDR3, 1600MHz |
2 × 2.5″ or 2 × 3.5″ | 1: 1 - x16 FH/FL | Dual 1Gb | ||
R320[130] | 1U Rack | C602 | 1 LGA 1356 | Xeon E5-2400 or E5-2400 v2 or E5-1400 | 192GB | 6, DIMM DDR3, 1600MHz |
16TB | 8 × 2.5″ or 4 × 3.5″ | 2: 1x16 FH/HL, 1x8 HH/HL | Broadcom Dual 1Gb | |
R420[131] | 1U Rack | C602 | 2 LGA 1356 | Xeon E5-2400 or E5-2400 v2 | 384 GB | 12, DIMM DDR3, 1600MHz |
16 TB | 8 × 2.5″ or 4 × 3.5″ | 2: 1x16 FH/HL, 1x16 HH/HL (with 2 cpu)
or 2: 1x16 FH/HL, 1x8 HH/HL (with 1 cpu) |
Broadcom Dual 1Gb | |
R520 | 2U Rack | C602 | 2 LGA 1356 | Xeon E5-2400 or E5-2400 v2 | 384 GB | 12, DIMM DDR3, 1600MHz |
32 TB | 8 x 2.5″ or 8 x 3.5″ | 1x16x HH/HL at 16x, 1x16x FH/FL at 8x, 2x16 FH/HL at 8x(with 2 cpu) | Broadcom Dual 1Gb | |
R620[132] | 1U Rack | 2012 | C600 | 2 LGA 2011 | Xeon E5-2600 or E5-2600 v2 |
1.5 TB | 24, DIMM DDR3, 1600MHz |
10 TB | 8 × 2.5″ or 4 × 3.5″ + 2 × PCIe SSD
or 10 × 2.5″ |
3: 2 - x16 FH/FL, 1 - x8 FH/FL or 2, 2 x x16 |
Broadcom or Intel 4× 1Gb or 2× 10Gb |
R720[126] | 2U Rack | 2012 | C600 | 2 LGA 2011 | Xeon E5-2600 or E5-2600 v2 |
768 GB | 24, DIMM DDR3, 1600Mhz |
25 TB | 8 × 3.5″ or 16 × 2.5″ | 7: 1x16 FH/FL, 3x8 FH/FL, 3x8 HH/HL | Broadcom or Intel 4× 1Gb or 2× 10Gb |
R720XD[127] | 2U Rack | 2012 | C600 | 2 LGA 2011 | Xeon E5-2600 or E5-2600 v2 |
768 GB | 24, DIMM DDR3, 1600Mhz |
38 TB | 26 × 2.5″ or 12 × 3.5″ + 2 × 2.5″ | 6: 2 - x16 FH/FL, 1 - x8 FH/FL, 3 - x8 HH/HL | Broadcom or Intel 4× 1Gb or 2× 10Gb |
R820[133] | 2U Rack | 2012 | C600 | 4 LGA 2011 | Xeon E5-4600 | 1.5 TB | 48, DIMM DDR3 1600MHz |
16 TB | 16 × 2.5″ | 7: 2 - x16 HL/FH, 1 - x8 HL/FH, 3 - x8 HL/HH, 1 - x8 HL/FH (for RAID controller) | Broadcom or Intel 4× 1Gb or 2× 10Gb |
R920[134] | 4U Rack | 2012 | C602J | 4 LGA 2011 | Xeon E7-4800 v2 | 6 TB | 96, DIMM DDR3 1600MHz |
28.8 TB | 24 × 2.5″ | Broadcom or Intel 4× 1Gb or 2× 10Gb | |
M420[135] | Blade 1/4 height |
2012 | C600 | 2 LGA 1356 | Xeon E5-2400 | 192 GB | 6, DIMM DDR3, 1600Mhz |
2 × 200 GB | 2 × 1.8" | Broadcom[lower-alpha 2] 2× 10 Gb LOM +1 Mezzanine slot | |
M520[136] | Blade 1/2 height |
2012 | C600 | 2 LGA 1356 | Xeon E5-2400 | 384 GB | 12, DIMM DDR3, 1600Mhz |
2 × SATA/SAS HDD/SSD | 2 × 2.5″ | Broadcom or Intel on board+2 Mezzanine slots | |
M620[137] | Blade 1/2 height |
2012 | C600 | 2 LGA 2011 | Xeon E5-2600 | 768 GB | 24, DIMM DDR3, 1600Mhz |
2 × 2.5″ | Broadcom or Intel on board+2 Mezzanine slots | ||
M820[138] | Blade full height |
2012 | C600 | 4 LGA 2011 | Xeon E5-4600 | 1.5 TB | 48, DIMM DDR3, 1600MHz |
4 × SAS HDD/SSD or 2 × PCIe flash SSD |
4 × 2.5″ | 2× 10 Gb Converged Ethernet Adaptor on board+2 Mezzanine slots | |
C6220 [139] | 2U Rack | 2012 | C600 | 8 LGA 2011 | Xeon E5-2600 | 2 TB | 64, DIMM DDR3, 1600MHz |
48 TB | 24 × 2.5″ or 12 × 3.5″ | 2× 1Gb LOM, 100 Mb mgt + opt. InfiniBand Mezzanine |
Other 12th Generation servers, which are comparable in capabilities with the above detailed M or R versions of the same model number, are:[140]
- PE T320 Tower
- PE T420 Tower
Generation 13
In September 2014 Dell introduced their 13th generation servers based on Intel Xeon
Model | Chassis | Year | Chipset | CPU (No.) | CPU (Type) | RAM (Max) |
RAM (Type) | Internal Storage (Max) |
Drive bays | PCI(e) 3.0 slots | On board network |
---|---|---|---|---|---|---|---|---|---|---|---|
T130[141] | Tower | 2015 | Intel C236 | 1 | Xeon E3-1200 v6 | 64 GB | 4, ECC DDR4 up to 2400 MT/s | 4 x 3.5” cabled HDD |
|
Broadcom Dual 1Gb | |
R230[142] | 1U Rack | 2015 | Intel C236 | 1 | Xeon E3-1200 v5 | 64 GB | 4, DDR4 up to 2133 MT/s |
|
2 x PCIe 3.0 slots | Broadcom Dual 1Gb | |
R330[143] | 1U Rack | 2015 | Intel C236 | 1 | Xeon E3-1200 v5 or Xeon E3-1200 v6 | 64 GB | 4, DDR4 up to 2133 MT/s |
|
2 x PCIe 3.0 slots + 1 slot for internal storage | 2 x 1Gb | |
R430[144] | 1U Rack | 2014 | Intel C610 | 1 / 2 | Xeon E5-2600 v3 | 384 GB | 12, DDR4 up to 2133 MT/s |
|
|
2 × x8 HL/HH x16 (2 CPU) |
|
R530[145] | 2U Rack | 2014 | Intel C610 | 1 / 2 | Xeon E5-2600 v3 | 384 GB | 12, DDR4, up to 2133 MT/s |
|
8 x 3.5″ HDD: SAS, SATA, NL-SAS, SSD | 3 × PCIe3.0 + 2 x PCIe2.0 |
|
R630[146] | 1U Rack | 2014[147] | Intel C610 | 2 | Xeon E5-2600 v3 or Xeon E5-2600 v4 | 768 GB | 24, DDR4 up to 2133 MT/s |
|
|
|
|
T630[148] | Tower or 5U Rack | 2014 | Intel C610 | 2 | Xeon E5-2600 v4 | 1.5 TB | 24, DDR4 up to 2133 MT/s |
|
|
|
2 × Intel 1Gb LOM |
M630[149] | Blade 1/2 height | 2014 | Intel C610 | 2 | Xeon E5-2600 v3 | 768 GB | 24, DDR4 up to 2133 MT/s |
|
2 × PCIe 3.0 (x8) mezzanine |
(19 different optional adapters available) | |
R730[150] | 2U Rack | 2014 | Intel C610 | 2 | Xeon E5-2600 v3 or Xeon E5-2600 v4 | 1.5 TB | 24, DDR4, up to 2133 MT/s |
|
|
|
|
R730xd[151] | 2U Rack | 2014 | Intel C610 | 2 | Xeon E5-2600 v3 | 768 GB | 24, DDR4 up to 2133 MT/s |
|
|
|
|
R830 | 2U Rack | 2016 | Intel C612 | 4 | Xeon E5-4600 v4 | 3 TB | 24, DDR4 up to 2400 MT/s | 61.4TB (16 × 2.5″ SSD) | 16 × 2.5″ SAS, SATA, NL-SAS, SSD drives |
|
|
FC830[152] | 2U Rack | 2016 | Intel C612 | 4 | Xeon E5-4600 v4 | 1.5 TB | 48, DDR4 up to 2400 MT/s |
|
|
| |
R930[153] | 4U Rack | 2015 | Intel C602J | 4 | Xeon E7-4800 v4 | 12 TB | DDR4 up to 2400 MT/s
Only with daughterboards |
|
|
|
|
C4130[154] | 1U Rack | 2016 | Intel C612 | 2 | Xeon E5 2600 v4 | 1TB | 16, DDR4 up to 2400MT/s | Up to 4x 2.5″ Drives with Tray | 2x PCIe 3.0 low profile Intel H OmniPath | ||
Model | Chassis | Year | Chipset | CPU (No.) | CPU (Type) | RAM (Max) |
RAM (Type) | Internal Storage (Max) |
Drive bays | PCI(e) 3.0 slots | On board network |
Generation 14
In July 2017 Dell EMC introduced their 14th generation servers, adding support for latest Intel Xeon Scalable Processors, better NVM support and other updates.[155]
Model | Chassis | Year | Chipset | CPU (No.) | CPU (Type) | RAM (Max) | RAM (Type) | Internal Storage (Max) | Drive bays | PCI(e) 3.0 slots | On board network |
---|---|---|---|---|---|---|---|---|---|---|---|
R240 | 1U Rack | 2018 | 1 | 64GB | 4, DDR4 up to 2666 MT/s | 4 x 3.5 SAS, SATA, or SSD | 2 x 1GbE LOM | ||||
R340 | 1U Rack | 2018 | 1 | 64GB | 4, DDR4 up to 2666 MT/s |
|
2 x 1GbE LOM | ||||
R440[156] | 1U Rack | 2017 | 2 | Xeon Bronze 31xx or Silver 41xx or Gold 51xx, 61xx |
1TB Max (768GB max memory is recommended for performance optimized configurations) | 16, DDR4 up to 2666 MT/s |
|
|
|
| |
T440[158] | Tower or 5U Rack | 2017 | 2 | Xeon Bronze 3[12]xx or Silver 4[12]xx or Gold 5[12]xx, up to 135W |
512 GB | 16, DDR4 up to 2666MT/s |
|
|
5 | 2 x 1Gb | |
T640[159] | Tower or 5U Rack | 2017 | Intel C620[160] | 2 | 1st and 2nd Generation Intel Xeon Scalable, up to 205W | 3TB | 24, DDR4 up to 2666MT/s |
|
|
Up to 8 PCIe Gen 3 | 2 x 10Gb |
R540[161] | 2U Rack | 2017 | Intel C620[162] | 2 | Intel Xeon scalable
Bronze 31xx or Silver 41xx or Gold 51xx or Gold 61xx |
1TB Max (768GB max memory is recommended for performance optimized configurations) | 16, DDR4 up to 2666 MT/s |
|
|
Up to 6 PCIe[163] |
|
R640[164] | 1U Rack | 2017 | Intel C620 | 2 | 1st and 2nd Generation Intel Xeon Scalable, up to 205W | 7.68TB | 24, DDR4 up to 2933 MT/s | max 76.8TB | Front
Rear
|
3 (x16/x16/x16) |
|
R740[165] | 2U Rack | 2017 | Intel C620 | 2 | 3 TB | 24, DDR4 up to 2666 MT/s | max 96TB | 16 x 2.5″ SAS/SATA |
| ||
R740XD[166] | 2U Rack | 2017 | Intel C620 | 2 | Intel Xeon scalable | 3 TB | 24, DDR4 up to 2666 MT/s |
|
|
| |
R940[167] | 3U Rack | 2017 | 4 | Intel Xeon Gold/Platinum | 6 TB | 48, DDR4 up to 2666 MT/s | 184.32TB max | 24 x 2.5” SAS/SATA (HDD/SSD) |
| ||
M640 | Blade 1/2 height | 2 | 2nd Generation Xeon Scalable | 2TB | 16, DDR4 up to 2933 MT/s | 12.8TB max | 2 x 2.5” SAS/SATA (HDD/SSD) |
| |||
FC640[168] | 1U | 2019 | 2 | 2nd Generation Xeon Scalable | 2TB | 16, DDR4 up to 2933 MT/s | 12.8TB | 2 x 2.5” SAS/SATA (HDD/SDD) |
| ||
C6420[169] | 2U Rack | 2017 | |||||||||
Model | Chassis | Year | Chipset | CPU (No.) | CPU (Type) | RAM (Max) | RAM (Type) | Internal Storage (Max) | Drive bays | PCI(e) 3.0 slots | On board network |
Generation 15
On 17 March 2021, Dell officially launched their 15th generation PowerEdge servers[170] with some models already available in 2019.
Model | Chassis | Year | Chipset | CPU (No.) | CPU (Type) | RAM (Max) | RAM (Type) | Internal Storage (Max) | Drive bays | PCIe 3.0/4.0 slots | On board network |
---|---|---|---|---|---|---|---|---|---|---|---|
R6515 | 1U Rack | 2019 | SoC | 1 | 2nd and 3rd generation AMD EPYC | 2 TB | 16, DDR4-3200, 8 channels | 32 TB |
|
0–2 |
|
R7515 | 2U Rack | 2019 | SoC | 1 | 2nd and 3rd generation AMD EPYC | 2 TB | 16, DDR4-3200, 8 channels | 112 TB |
|
0–4 |
|
R7525 | 2U Rack | 2019 | SoC | 2 | 2nd and 3rd generation AMD EPYC | 4 TB | 32, DDR4-3200, 16 channels | 112 TB |
|
0–8 |
|
Model | Chassis | Year | Chipset | CPU (No.) | CPU (Type) | RAM (Max) | RAM (Type) | Internal Storage (Max) | Drive bays | PCIe 3.0/4.0 slots | On board network |
PowerEdge SC Value Servers
Independent from the main generations of servers a value line was produced.
Model | Chassis | Year | Chipset | CPU (No. & Socket) | CPU (Type) | RAM (Max) | RAM (Type) | Drive bays | Comments |
---|---|---|---|---|---|---|---|---|---|
300 SC[171] | Tower | Intel 440BX | Pentium III | 1 GB | 4, ECC reg PC-100 | ||||
1400 SC[172] | Tower | 2000 | 2 | Pentium III | 2 GB | 4, ECC reg PC-133 | Ultra3 SCSI controller | ||
500 SC[173] | Tower | 2001[174] | ServerWorks ServerSet LE 3.0 | 1 | Pentium III 1.0+ or Celeron 800Mhz+ | 2 GB | 4, ECC PC-133 | ||
1500 SC[175] | Tower | 2 | Pentium III 1.1 GHz | 4 GB | 4, ECC reg PC-133 | 6 hot-swappable Ultra3 SCSI HDD bays | |||
600 SC[176] | Tower | 2003 | ServerWorks GC-SL | 1 | Pentium 4 2.0+ or Celeron 1.7+ | 4 GB | 4, ECC DDR 200 | ||
1600 SC[177] | Tower | 2004 | ServerWorks GC-SL | 2 | Xeon at up to 3.2 GHz | 4 GB | 4, ECC DDR 266 | ||
420 SC[178] | Tower | 2004 | Intel E7221 | 1 | Pentium 4 or Celeron | 4 GB | 4, ECC DDR2 400–533 | ||
1420 SC[179] | Tower | 2004 | Intel E7520 | 2 Socket 604 | Xeon, 800Mhz FSB | 8 GB | 6, ECC DDR2-400 | (3) internal 3.5″ (2) 5.25 external up to 4 HDD |
|
1425 SC[180] | 1U Rack | Intel E7520 | 2 | Xeon, 800Mhz FSB | 12 GB | 6, ECC DDR2 400 | up to 4 HDD | ||
430 SC[181] | Tower | 2005 | Intel E7230 | 1 LGA 775 | Pentium 4 or Celeron D | 4 GB | 4, ECC DDR2 533 | (2) ext. 5.25″ (1) ext. 3.5″ (2) int. 3.5″ |
|
1430 SC[182] | Tower | 2006 | Intel 5000V | 2 LGA 771 | Xeon 5300, Xeon 5100, Xeon 5000 | 16 GB | 4, ECC DDR2 533-667 MHz | 4 3.5″ SAS or SATA | |
1435 SC[183] | 1U Rack | 2007 | Broadcom HT-2100 and HT-1000 | 2 Socket F | Opteron 2200 or 2300 | 32 GB | 8, ECC DDR2 667 | 1 slimline bay | |
440 SC[184] | Tower | 2006 | Intel 3000 | 1 | Xeon 3000, Pentium D or Celeron D | 8 GB | 4, ECC DDR2 533–667 | 2 3.5″ SATA or SAS 2 5.25″ | Although Dell's literature says the max RAM is 4GB, several people have had success running it with 8GB RAM total |
Notes
References
- ↑ 1.0 1.1 Serverwatch website Spotlight on Dell, 15 May 2008, visited 28 June 2011
- ↑ https://www.dell.com/support/article/us/en/04/sln294897/how-to-identify-which-generation-your-dell-poweredge-server-belongs-to?lang=en
- ↑ Infoworld website Dell revamps Poweredge line, 12 November 2007, visited 28 June 2011
- ↑ Dornbusch, Margaret (May 1, 1995). "Bevy of new servers spring up". Network World (Framingham, Massachusetts: IDG Network World) 12 (18): 23. ISSN 0887-7661.
- ↑ "Benchmark Tests: File Servers". PC Magazine (Ziff Davis, Inc.) 13 (17): 218. October 11, 1994. Benchmark Tests: File Servers
- ↑ 6.0 6.1 6.2 6.3 6.4 6.5 Dell PowerEdge SP 5100-2/5133-2/5166-2 manual
- ↑ 7.0 7.1 DeVoe, Deborah (November 20, 1995). "Dell joins Internet parade with Web server". InfoWorld (San Francisco, California: InfoWorld Media Group) 17 (47): 6. ISSN 0199-6649.
- ↑ Dell PowerEdge XL 5133-4 manual
- ↑ Dell PowerEdge 2100 Service Manual
- ↑ Dell PowerEdge 4100 User Guide
- ↑ Dell PowerEdge 6100 User Guide
- ↑ Dell PowerEdge 2200 User Guide
- ↑ Dell PowerEdge 4200 Specifications
- ↑ Dell PowerEdge 350 Technical Specification
- ↑ Dell PowerEdge 1300 Technical Specifications
- ↑ Dell PowerEdge 2300 Technical Specifications
- ↑ Dell PowerEdge 4300 Technical Specifications
- ↑ Dell PowerEdge 4350 User Guide
- ↑ Dell PowerEdge 6300 Technical Specifications
- ↑ Dell PowerEdge 6350 Technical Specifications
- ↑ Dell PowerEdge 2400 Technical Specifications
- ↑ PC Pro review of the Dell PowerEdge 2400
- ↑ Dell PowerEdge 2450 Technical Specifications
- ↑ Dell PowerEdge 4400 Technical Specifications
- ↑ Dell PowerEdge 6400 Technical Specifications
- ↑ Dell PowerEdge 6450 Technical Specifications
- ↑ Dell PowerEdge 8450 Technical Specifications
- ↑ Novell, Dell PowerEdge 8450 Netwear test report
- ↑ Dell PowerEdge 1550 Technical Specifications
- ↑ PC Pro review of the Dell PowerEdge 1550
- ↑ Dell PowerEdge 2500 Technical Specifications
- ↑ Dell PowerEdge 2550 Technical Specifications
- ↑ Dell PowerEdge 3250 Specification Sheet
- ↑ Dell PowerEdge 7150 Technical Specifications
- ↑ PC Pro review of the Dell PowerEdge 7150
- ↑ Dell PowerEdge 7250 Specification Sheet
- ↑ Dell PowerEdge 650 Specification Sheet
- ↑ Dell PowerEdge 1650 Technical Specifications
- ↑ Novell, Dell PowerEdge 1650 Netware test report
- ↑ Dell PowerEdge 1655MC Specification Sheet
- ↑ Dell PowerEdge 2600 Specification Sheet
- ↑ Dell PowerEdge 2650 Specification Sheet
- ↑ Dell PowerEdge 4600 Specification Sheet
- ↑ 44.0 44.1 Dell PowerEdge 66X0 Specification Sheet
- ↑ Dell PowerEdge 700 Specification Sheet
- ↑ Dell PowerEdge 750 Specification Sheet
- ↑ Dell PowerEdge 1750 Specification Sheet
- ↑ Dell PowerEdge 800 Specification Sheet
- ↑ Dell PowerEdge 830 Specification Sheet
- ↑ Dell PowerEdge 840 Specification Sheet
- ↑ PowerEdge 840 A08 BIOS Release Notes
- ↑ Dell PowerEdge 1800 Technical Specifications
- ↑ Dell PowerEdge 1850 Specification Sheet
- ↑ Dell PowerEdge 1855 Specification Sheet
- ↑ Dell PowerEdge 2800 Specification Sheet
- ↑ Dell PowerEdge 2850 Specification Sheet
- ↑ Dell PowerEdge 6800 Specification Sheet
- ↑ Dell PowerEdge 6850 Specification Sheet
- ↑ Dell PowerEdge 850 Info brief
- ↑ Dell PowerEdge 860 Specification Sheet
- ↑ PowerEdge 860 A05 BIOS Release Notes
- ↑ Dell PowerEdge 1900 Specification Sheet
- ↑ Dell PowerEdge 1950 Specification Sheet
- ↑ Dell PowerEdge 1955 Specification Sheet
- ↑ Dell PowerEdge 2900 Specification Sheet
- ↑ Dell PowerEdge 2950 Specification Sheet
- ↑ Dell PowerEdge 2950 III Specification Sheet
- ↑ Dell PowerEdge 1950/2950 Memory Capacity
- ↑ Dell PowerEdge 2970 Specification Sheet
- ↑ PC Pro Review of the Dell Power PowerEdge 2970
- ↑ Dell PowerEdge 6950 Specification Sheet
- ↑ PC Pro Review of the Dell Power PowerEdge 6950
- ↑ Dell PowerEdge T100 Specification Sheet
- ↑ PC Pro review of Dell PowerEdge T100
- ↑ Dell PowerEdge T105 Specification Sheet
- ↑ Dell PowerEdge R200 Specification Sheet
- ↑ Dell PowerEdge T300 Specification Sheet
- ↑ Dell PowerEdge R300 Specification Sheet
- ↑ Dell PowerEdge M600 Blade Server
- ↑ Dell PowerEdge T605 Specification Sheet
- ↑ PC Pro review of Dell PowerEdge T605
- ↑ Dell PowerEdge M605/E1000E Specification Sheet
- ↑ Dell PowerEdge R805 Specification Sheet
- ↑ PC Pro review of Dell PowerEdge R805
- ↑ Dell PowerEdge M805 Specification Sheet
- ↑ Dell PowerEdge R900 Specification Sheet
- ↑ Dell PowerEdge R905 Specification Sheet
- ↑ Dell PowerEdge M905 Specification Sheet
- ↑ Dell PowerEdge T110 Specification Sheet
- ↑ Dell PowerEdge T110 II Specification Sheet
- ↑ Dell PowerEdge R210 Specification Sheet
- ↑ Dell PowerEdge R210 II Specification Sheet
- ↑ Dell PowerEdge T310 Specification Sheet
- ↑ Dell PowerEdge R310 Specification Sheet
- ↑ Dell PowerEdge T410 Specification Sheet
- ↑ PC Pro review of Dell PowerEdge T410
- ↑ Dell PowerEdge R410 Specification Sheet
- ↑ PC Pro review of Dell PowerEdge R410
- ↑ Dell PowerEdge R415 Specification Sheet
- ↑ 100.0 100.1 https://www.dell.com/support/article/nz/en/nzdhs1/sln155889/memory-information-for-11th-generation-amd-processor-servers?lang=en
- ↑ Dell PowerEdge R510 Specification Sheet
- ↑ Dell PowerEdge R515 Specification Sheet
- ↑ Dell PowerEdge T610 Specification Sheet
- ↑ Dell PowerEdge R610 Specification Sheet
- ↑ Dell PowerEdge M610 Specification Sheet
- ↑ Dell PowerEdge T710 Specification Sheet
- ↑ Dell PowerEdge R710 Specification Sheet
- ↑ PC Pro review of Dell PowerEdge R710
- ↑ Dell PowerEdge R710 System Boards (Motherboards)
- ↑ Dell PowerEdge R715 Specification Sheet
- ↑ PC Pro review of Dell PowerEdge R715
- ↑ Dell PowerEdge M710 Specification Sheet
- ↑ Dell PowerEdge R810 Specification Sheet
- ↑ Stevens, Alan (June 25, 2010). "Dell PowerEdge R810". ZDNet. http://www.zdnet.co.uk/reviews/sme-servers/2010/06/25/dell-poweredge-r810-40089356/. Retrieved March 7, 2012.
- ↑ Dell PowerEdge R810 System Memory Update
- ↑ Dell PowerEdge R815 Specification Sheet
- ↑ Dignan, Larry (March 30, 2010). "Dell PowerEdge R815". ZDNet. http://www.zdnet.com/blog/btl/dell-launches-new-intel-nehalem-ex-servers-amd-opteron-addition/. Retrieved April 13, 2012.
- ↑ Dell PowerEdge R910 Specification Sheet
- ↑ "dell R910 spec". https://www.dell.com/downloads/global/products/pedge/spc_r910_new.pdf.
- ↑ Intel® Xeon® Processor 7500 Series Datasheet, Volume 2
- ↑ Dell PowerEdge M910 Specification Sheet
- ↑ Dell PowerEdge C1100 Specification Sheet
- ↑ Dell PowerEdge C2100 Specification Sheet
- ↑ Dell PowerEdge C6100 Specification Sheet
- ↑ 125.0 125.1 125.2 Overview page about the Poweredge 12th generation servers, visited 7 March 2012
- ↑ 126.0 126.1 "Dell PowerEdge R720 Spec Sheet" (PDF). https://i.dell.com/sites/content/shared-content/data-sheets/en/Documents/Dell-PowerEdge-R720-Spec-Sheet.pdf.
- ↑ 127.0 127.1 "Dell PowerEdge R720XD Spec Sheet" (PDF). https://i.dell.com/sites/content/shared-content/data-sheets/en/Documents/Dell-PowerEdge-R720XD-Spec-Sheet.pdf.
- ↑ Dell website: Poweredge T620 Technical specifications, visited 7 March 2012
- ↑ Dell website: Poweredge R220 Technical specifications, visited 2 October 2014
- ↑ Dell website: Poweredge R320 Technical specifications, visited 24 March 2016
- ↑ Dell website: Poweredge R420 Technical specifications, visited 2 October 2014
- ↑ Dell website: Poweredge [1], visited 7 March 2012
- ↑ Dell website: Poweredge PowerEdge R820 rack server details, visited 06 February 2012
- ↑ Dell website: Poweredge PowerEdge R920 rack server details, visited 05 May 2019
- ↑ Dell website: Poweredge M420 Technical specifications, visited 17 July 2012
- ↑ Dell website: Poweredge M520 Technical specifications, visited 28 July 2012
- ↑ Dell website: Poweredge M620 Technical specifications, visited 7 March 2012
- ↑ Dell website: Poweredge M820 Technical specifications, visited 28 July 2012
- ↑ Dell website: Poweredge C6220 Technical specifications, visited 28 July 2012
- ↑ Overview 12th Generation servers, Dell website. Visited 28 July 2012
- ↑ Dell PowerEdge T130 Specification Sheet
- ↑ Dell PowerEdge R230 Specification Sheet
- ↑ Dell PowerEdge R330 Specification Sheet
- ↑ Dell PowerEdge R430 Specification Sheet
- ↑ Dell PowerEdge R530 Specification Sheet
- ↑ Dell PowerEdge R630 Specification Sheet
- ↑ Dell 13th Generation PowerEdge Server Resources, Dell website. Visited 17 February 2015
- ↑ Dell PowerEdge T630 Specification Sheet
- ↑ "Dell PowerEdge M630 Specification Sheet". i.dell.com. https://i.dell.com/sites/csdocuments/Shared-Content_data-Sheets_Documents/en/aa/Dell-PowerEdge-M630-Spec-Sheet.pdf.
- ↑ Dell PowerEdge R730 Specification Sheet
- ↑ Dell PowerEdge R730xd Specification Sheet
- ↑ "Dell PowerEdge FC830 SpecSheet". https://i.dell.com/sites/doccontent/shared-content/data-sheets/en/Documents/Dell_PowerEdge_FC830_SpecSheet.pdf.
- ↑ Dell PowerEdge R930 Specification Sheet
- ↑ Dell EMC PowerEdge C6420 Specification Sheet
- ↑ Press Release about 14th generation
- ↑ Dell EMC PowerEdge R440 Specification Sheet
- ↑ "Dell PowerEdge R440 Server". https://www.serverbasket.com/shop/dell-poweredge-r440-server-price-india/.
- ↑ Dell EMC PowerEdge T440 Specification Sheet
- ↑ "Dell EMC PowerEdge T640 Specification Sheet". https://i.dell.com/sites/csdocuments/Shared-Content_data-Sheets_Documents/en/PowerEdge-T640-Spec-Sheet.pdf.
- ↑ "Dell EMC PowerEdge T640. Technical Guide". https://i.dell.com/sites/csdocuments/Product_Docs/en/poweredge-t640-technical-guide.pdf.
- ↑ "Dell PowerEdge R540 Server Specifications 2019". https://i.dell.com/sites/csdocuments/Shared-Content_data-Sheets_Documents/en/PowerEdge-R540-Spec-Sheet.pdf.
- ↑ "Dell EMC PowerEdge R540 System. Technical Guide". https://i.dell.com/sites/csdocuments/Shared-Content_data-Sheets_Documents/en/us/poweredge-r540-technical-guide.pdf.
- ↑ "Dell EMC PowerEdge R540 Server Overview". https://topics-cdn.dell.com/pdf/poweredge-r540_reference-guide2_en-us.pdf.
- ↑ Dell EMC PowerEdge R640 Technical Guide
- ↑ Dell EMC PowerEdge R740 Specification Sheet
- ↑ Dell EMC PowerEdge R740XD Specification Sheet
- ↑ Dell EMC PowerEdge R940 Specification Sheet
- ↑ Dell EMC PowerEdge FC640 Specification Sheet
- ↑ Dell EMC PowerEdge C6420 Specification Sheet
- ↑ "Dell Technologies Powers AI and Edge Computing with Next Generation PowerEdge Servers". 2021-03-17. https://corporate.delltechnologies.com/en-us/newsroom/announcements/detailpage.press-releases~usa~2021~03~20210317-dell-technologies-powers-ai-and-edge-computing-with-next-generation-poweredge-servers.htm. Retrieved 2021-03-24.
- ↑ Dell PowerEdge 300 Technical Specification
- ↑ Dell PowerEdge 1400SC Technical Specifications
- ↑ Dell PowerEdge 500SC Technical Specification
- ↑ PC Mag review of the Dell PowerEdge 500SC
- ↑ Dell PowerEdge 1500SC Technical Specifications
- ↑ Dell PowerEdge 600SC Specification Sheet
- ↑ Dell PowerEdge 1600SC Specification Sheet
- ↑ Dell PowerEdge SC420 Specification Sheet
- ↑ Dell PowerEdge SC1420 Specification Sheet
- ↑ Dell PowerEdge SC1425 Technical Specifications
- ↑ Dell PowerEdge SC430 Specification Sheet
- ↑ Dell PowerEdge SC1430 Specification Sheet
- ↑ Dell PowerEdge SC1435 Specification Sheet
- ↑ Dell PowerEdge SC440 Specification Sheet
External links