Engineering:Thermal work limit
Thermal Work Limit (TWL) is defined as the limiting (or maximum) sustainable metabolic rate that well-hydrated, acclimatized individuals can maintain in a specific thermal environment, within a safe deep body core temperature (< 38.2 °C or 100.8 °F) and sweat rate (< 1.2 kg or 2.6 lb per hour).[1] The index is designed for self-paced workers and does not rely on estimation of actual metabolic rates, a process that is difficult and subject to considerable error. The index has been introduced into the United Arab Emirates[2] and Australia , resulting in a substantial and sustained fall in the incidence of heat illness in the latter.[3]
History
The idea of a thermal work limit (TWL) was developed by Dr. Graham Bates and Dr. Derrick Brake in 1997.[4] Over the past 80 years, many heat stress indices have been developed to assist with the management of heat stress problems. Some of these have been developed for particular industries and empirically derived such as ISO 7933 and WBGT. [5][6] These indices required estimation of metabolic rate but failed to consider the direct measurement of wind speed, reduction of work rate, location and time shift during work and removal of clothing, making these indices not accurate for self-paced and acclimatized workers.[7][8] The need for a heat stress index designed primarily for self-paced workers has led to the development of the thermal work limit (TWL). TWL and its accompanying management protocols have been introduced into several industrial operations where workers are subject to thermal stress. Approximately 1400 persons work in these locations with over 10 million man-shifts being worked between 1965 and 1995 at wet bulb temperatures in excess of 28 °C (82 °F). Since the introduction of TWL-based policies in the Australian mining industry, the amount of man-hours lost due to serious heat illness has fallen from 12 million to 6 million, and the amount lost due to all heat illness incidences[spelling?] has fallen from 31 million to 18 million.[9]
Theory
The basic purpose of the thermal work limit index is to calculate the maximum metabolic rate, in watts of metabolic heat per square meter of body surface area, that can be continuously expended in a particular thermal environment, in order to keep the body within safe physiological limits. The TWL is an integrated measure of the dry bulb, wet bulb, wind speed and radiant heat. From these variables, and taking into consideration the type of clothing worn and the acclimatization state of the worker, the TWL predicts the maximum level of work that can be carried out in a given environment, without workers exceeding a safe core body temperature 38.2 °C (100.8 °F) and sweat rate. The index can also determine the safe work duration, in excessively hot conditions, thus providing guidelines for work/rest cycling. Sweat rates are also calculated, so the level of fluid replacement necessary to avoid dehydration can be established. The thermal work limit algorithm builds on work originated by Mitchell and Whillier,[10] who developed an index “specific cooling power,” which subsequently became known as “air cooling power” (ACP).
Methodology
To determine TWL the following must be measured[2]:
- Dry Bulb Temperature (ambient air temperature) (in degrees °C)
- Wet Bulb Temperature (determined by the humidity/evaporation) (in degrees °C)
- Globe Temperature (determined by the radiant heat) (in degrees °C)
- Wind speed in meters per second
The thermal environment can be classified on the basis of TWL into the working zones shown in the adjacent image.
Application
The TWL heat stress index is the heat stress index that has been included in the Abu Dhabi EHSMS code of practice for the management of Heat Stress.[11] TWL gives a measure of the maximum safe work rate for the environmental conditions present at a worksite. If TWL is too low then even low rates of work cannot safely be carried out continuously and extra rest breaks and other precautions are needed to ensure worker safety.[9]
References
- ↑ Brake, D. J.; Bates, G. P. (2002). "Limiting Metabolic Rate (Thermal Work Limit) as an Index of Thermal Stress". Applied Occupational and Environmental Hygiene 17 (3): 176–186. doi:10.1080/104732202753438261. PMID 11871754.
- ↑ 2.0 2.1 "The Thermal Work Limit Heat Stress Index". Health Authority - Abu Dhabi. http://www.haad.ae/Safety-In-Heat/Default.aspx?tabid=94.
- ↑ Miller, V. S.; Bates, G. P. (2007). "The Thermal Work Limit is a Simple Reliable Heat Index for the Protection of Workers in Thermally Stressful Environments". Annals of Occupational Hygiene 51 (6): 553–561. doi:10.1093/annhyg/mem035. PMID 17878259.
- ↑ Brake, D.J.; Donoghue, M.D.; Bates, G.P. (August 1998), A New Generation of Health and Safety Protocols for Working in Heat, http://www.aqualyte.com.au/pdf/Working%20In%20Heat%20Principles%20paper.pdf
- ↑ ASHRAE Handbook: Fundamentals, Atlanta: ASHRAE, 1997
- ↑ "Hot Environments – Analytical Determination and Interpretation of Thermal Stress Using Calculation of Required Sweat Rate (1st ed.)", Iso 7933 (Geneva, Switzerland: International Organization for Standardization), 1989
- ↑ Hanson, M. (1999). "Development of a draft British Standard: The assessment of heat strain for workers wearing personal protective equipment". The Annals of Occupational Hygiene 43 (5): 309–319. doi:10.1016/S0003-4878(99)00053-8. PMID 10481630.
- ↑ Bricknell, M. C. M. (1996). "Heat Illness in the Army in Cyprus". Occupational Medicine 46 (4): 304–312. doi:10.1093/occmed/46.4.304. PMID 8854710.
- ↑ 9.0 9.1 Brake, D. J.; Bates, Graham (2000). "Occupational heat illness: an interventional study". International Conference on physiological and cognitive performance in extreme environments. Canberra.
- ↑ Mitchell, D.; Whillier, A. (1971), "Cooling power of underground environments", Journal of the South African Institute of Mining and Metallurgy 71: 93–9
- ↑ Abu Dhabi EHSMS Regulatory Framework (AD EHSMS RF): Technical Guideline: Safety in the Heat, 2.1, April 2013, http://www.adehsms.ae/Documents/ADEHSMS/05_Guidelines/Technical%20Guidelines/AD%20EHSMS%20RF%20-%20TG%20-%20Safety%20in%20the%20Heat.pdf
External links
Original source: https://en.wikipedia.org/wiki/Thermal work limit.
Read more |