| Device | Photo | Mfg. country | Size, mm | Weight, g | Power supply | Display | Sound | Vibration | Detector type | Range, μSv/h | Range, μR/h | Measurement time, seconds | Measuring of beta and gamma radiation and range of energy | PC link | Extra features |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Radmetron PM1211[1] | 128x48x20 | 130 | 1 CR2450 | LCD | Yes | No | Geiger–Müller tube | 0.01 – 10e4 | 1.14 – 11.4e6 | yes (48 keV – 3 MeV) | USB | ||||
| Radmetron PM1300[2] | 85x57x21 | 95 | AAA | LCD | Yes | Yes | Silicon PIN diode | 0.01 – 10e6 | 1.14 – 11.4e5 | 0 – 20 | X-ray and Gamma (15 keV – 20 MeV) | USB, RF-interface | GPS | ||
| Radmetron PM1300GN[3] | 130х57х35 | 200 | built-in rechargeable, or optional AAA | LCD | Yes | Yes | Silicon PIN diode, scintillator, silicon photomultiplier | 0.01 – 10e3 | 1.14 – 11.4e7 | 0 – 20 | Yes (0.025 eV – 15 MeV for neutron radiation, 15 keV – 20 MeV for photon radiation) | USB, RF-interface | |||
| Radmetron PM1401GNM[4][lower-alpha 1] | 195х57х32 | 450 | 1 АА | LCD | Yes | Yes | 3He, Geiger–Müller tube, CsI(Tl) scintillator | 0.1 – 9999 ±20% | 0.25 | Yes (0.033 – 3 MeV for gamma, 0.025 eV– 14 MeV for neutron) | USB | ||||
| Radmetron PM1401MA[5] | 110×62×38 | 320 | 1 АА | LCD | Yes | Yes | CsI(Tl) scintillator | 0.05 – 40 ±20% | 0.25 | Yes (0.05 – 3 MeV) | USB | ||||
| Radmetron PM1401K-3[6] | 262x60x65 | 820 | 2 АА | Color LCD | Yes | Yes | 3He, Geiger–Müller tube, CsI(Tl) scintillator | 0.1 μSv/h – 100 mSv/h | Yes (150 keV – 3.5 MeV for beta radiation, 15 keV – 15 MeV for photon radiation) | USB | GPS | ||||
| Radmetron PM1401K-3M[6] | 262x60x65 | 820 | 2 АА | Color LCD | Yes | Yes | Geiger–Müller tube, CsI(Tl) scintillator | 0.1 μSv/h – 100 mSv/h | Yes (150 keV – 3.5 MeV for beta radiation, 15 keV – 15 MeV for photon radiation) | USB | GPS | ||||
| Radmetron PM1405P[7][lower-alpha 2] | 136×69×38 | 340 | 1 АА | Yes | No | Geiger–Müller tube | 0.1 – 3e5 ±20% | 11.4 – 34.2e6 ±20% | Yes (50 keV – 3 MeV) | USB | |||||
| Radmetron PM1603A[8] | 50х56х19 | 85 | 1 CR2032 | LCD with backlight | Yes | No | Geiger–Müller tube | 0.01 – 10e3 | 1.14 – 11.4e2 | Yes (48 keV – 3 MeV) | IR adapter | alarm clock, timer, stopwatch, calendar | |||
| Radmetron PM1603B[9] | Yes | No | Yes (48 keV – 3 MeV) | ||||||||||||
| Radmetron PM1611[10] | 60×65×22 | ≤70 | built-in rechargeable | LCD | Yes | Yes | Geiger–Müller tube | 0.1 – 10e6 ±15% | 11.4 – 11.4e8 ±15% | 0 – 2 | Yes (20 keV – 10 MeV) | USB | |||
| Radmetron PM1611B[10] | 60×65×25 | ≤80 | AAA | LCD | Yes | Yes | Geiger–Müller tube | 0.1 – 10e6 ±15% | 11.4 – 11.4e8 ±15% | 0 – 2 | Yes (20 keV – 10 MeV) | USB | |||
| Radmetron PM1621[11] | 87х72х39 | 150 | 1 АА | LCD | Yes | No | Geiger–Müller tube | 0.1 – 10e4 ±15% | 11.4 – 11.4e6 ±15% | Yes (10 KeV – 20 MeV) | IR adapter | ||||
| Radmetron PM1621A[12] | 87х72х39 | 165 | 1 АА | LCD | Yes | No | Geiger–Müller tube | 0.1 – 10e5 ±15% | 11.4 – 11.4e7 ±15% | Yes (10 KeV – 20 MeV) | IR adapter | ||||
| Radmetron PM1621M[13] | 87х72х39 | 185 | 1 АА | LCD | Yes | No | Geiger–Müller tube | 0.01 – 10e4
±15% |
11.4 – 11.4e6 ±15% | Yes (10 keV – 20 MeV) | IR adapter | ||||
| Radmetron PM1621MA[14] | 87х72х39 | 185 | 1 АА | LCD | Yes | Yes | Geiger–Müller tube | 0.01 – 10e5
±15% |
11.4 – 11.4e7 ±15% | Yes (10 KeV – 20 MeV) | IR adapter | ||||
| Ludlum Model 23[15] | 112.8x30x12 | 55.9 | CR2450 | OLED | Yes | No | MOSFET | 1 – 99.1e4 ≤±10% | 114 – 11.4e7 ≤±10% | X-ray and Gamma | IR reader | ||||
| Ludlum Model 23-1[16] | 112.8x30x12 | 55.9 | CR2450 | OLED | Yes | No | MOSFET | 1 – 99.9e3 ≤±10% | 114 – 11.47 ≤±10% | Gamma and X-ray | IR reader | ||||
| Ludlum Model K8[17] | 39x25x13 | 13 | CR2032 | LED | Yes | No | MOSFET | 0.01 – 99.9e7 | gamma | No | |||||
| Ludlum Model 25[18][19][20] | 76x54x17 | 144 | 2 lithium button cells | LCD with backlight | Yes | No | Geiger–Müller tube | 0.1 – 87.6e5 | 10 – 99.9e7 | Yes (60 keV – 2 MeV) | |||||
| Ludlum Model 25-1[18][19][20] | 76x54x17 | 144 | 2 lithium button cells | LCD with backlight | Yes | No | Geiger–Müller tube | 1 – 99.9e5 | 114 – 11.4e8 | Yes (60 keV — 2 MeV) | |||||
| Ludlum Model 25-IS[18][19][21] | 76x54x17 | 144 | 2 lithium button cells | LCD with backlight | Yes | No | Geiger–Müller tube | 0.09 —87.6e5 | 10 —99.9e7 | Yes (60 keV — 2 MeV) | |||||
| Ludlum Model 25-IS-1[18][19][21] | 76x54x17 | 144 | 2 lithium button cells | LCD with backlight | Yes | No | Geiger–Müller tube | 1 — 99.9e5 | 114 — 11.4e8 | Yes (60 keV — 2 MeV) | |||||
| FNIRSI GC-01[22] | 120x78x27 | 1100mAh Lithium-ion battery | LCD with backlight | Yes | Yes | Geiger–Müller tube | 0.01 — 50e3 | 1 — 50e5 | combined, 48 keV - 1.5 Mev ≤ ±30% | Hydrogen Cyanide Detector | |||||
| FNIRSI GC-02[23] | 850 mAh Lithium-ion battery | LCD with backlight | Yes | Geiger–Müller tube | Yes | ||||||||||
| Radiascan 501[24][25] | 110х60х23 | 110 | 2 AAA battery | Color OLED display | Yes | No | Geiger–Müller tube Beta 1-1 | 0.01—10e3 | 1—10e5 | 1 — 60 | No | Yes | food contamination tester, "background pattern analysis algorithm"[lower-alpha 3] | ||
| SA-05A[26] | 48x64px | 119x65x26.5 | 135 | Built-in lithium polymer battery | LCD | No | No | Geiger–Müller tube LND 713 | 0.01–6000 | No | 1 – 60 | 0.05–1.3 MeV | USB | Clock, calendar and data logger | |
| Radiascan 701[24] | 48px | 110х60х23 | 110 | 2 AAA battery | Color OLED display | Yes | No | Geiger–Müller tube Beta 1-1 | 0.01—10e3 | 1—10e5 | 1 — 60 | Combined | USB | food contamination tester | |
| ANRI 01-02 Sosna[27][24] | 48x64px | 133x82x45 | 350 | Nine-volt battery | LCD | Yes | No | Two to four Geiger–Müller tubes | 0.1–100 | 10–10e4 | 20±5 | Combined, 0.5–3.0 MeV | No | ||
| bGeigie Nano[28][29] | 149x103x54 | 440 | Li-Po | LCD | No | Yes | one Geiger–Müller tube | 0–1000 | 0–100 | 1 – 60 | Yes | USB, Bluetooth, and WiFi | Waterproof,Clock GPS, open-source | ||
| bGeigieZen Standard[28][30] | 165x98x52 | 450 | replaceable 18650 3000mA
+ USB-C +QI wireless |
IPS LCD with touchscreen | yes (can be switched on/off) | No | one LND7317 Geiger–Müller tube | 0-1000 | 0-100 | 1 — 60 | USB, Bluetooth, and WiFi | Waterproof, GPS, open-source.
WiFi and BLE real time and upload of data. | |||
| bGeigieZen NFW[30] | 165x98x52 | 450 | replaceable 18650 3000mA
+ USB-C +QI wireless |
IPS LCD with touchscreen | yes (can be switched on/off) | No | one LND7317 Geiger–Müller tube | 0-1000 | 0-100 | 1 — 60 | USB, Bluetooth, and WiFi | Waterproof, GPS, open-source.
WiFi and BLE real time and upload of data. | |||
| DKG-RM1203M[31] | 125x42x24 | 90 | Two LR44 | LCD | Yes | No | Geiger–Müller tube | 0.01–2000 | 1–2*10e5 | No | Infrared | Clock with alarm | |||
| DKR-04 | 74х48х16 | 50 | AAA | LCD | Yes | No | Semiconductor | 0.1–10e6 | 10–10e8 | 4 — 256 | No | No | |||
| Ecotest DKG-21M[32] | 98×58×18 | 140 | CR2450 Button cell | Yes | Geiger–Müller tube | 0.1 – 10e5
±15% |
Yes (0.05 – 6 MeV) | infrared | |||||||
| Ecotest DKG-24 "PRD Guarder"[33] | 60×110×30 | 250 | 2 АА | backlit monochrome display | Yes | Yes | CsI(Tl) scintillator, silicon semiconductor | 0.01 – 107 | 10 – 90 | Yes (0.02 – 10.0 MeV) | Bluetooth, USB | gyroscope, GPS | |||
| Ecotest MKS-03D "Swift" | 111x73x28 | 200 | 2 АА | LCD with backlight | Yes | Yes | Geiger–Müller tube | 0.1—105 | 10—107 | 4 — 128 | Combined, 0.12—3.0 MeV Beta measurement range 5—105 min−1 cm−2 | USB | Clock with alarm, optional case | ||
| Ecotest MKS-05 "Terra-P" | 48x64px | 120×52×26 | 150 | Two AAA | LCD | Yes | No | Geiger–Müller tube | 0.1–1000 | 10–10e5 | 5 — 70 | Combined, 0.5–3.0 MeV | No | Clock with alarm, cover as option | |
| Ecotest MKS-05 "Terra" (New edition) | 120×52×26 | 150 | Two AAA | LCD with backlight | Yes | Yes | Geiger–Müller tube | 0.1–10e4 | 10–10e6 | 1 — 70 | Combined, 0.5–3.0 MeV | Bluetooth | Clock with alarm, cover | ||
| Ecotest MKS-05 "Terra" (with Bluetooth channel)[34] | 120×52×26 | 150 | Two AAA | LCD with backlight | |||||||||||
| Ecotest MKS-UM | 166×70×132 (control unit), 47×95×173 (probe) | 70 (control unit), 30 (probe) | Yes | Geiger–Müller tube | 1 – 10e6 | Yes (0.05 – 3 MeV) | |||||||||
| Ecotest RKS-01 "STORA-TU" | 160×75×36 | 50 | Two AAA | Yes | 4 Geiger–Müller tubes | 0.1 – 999.9 | Bluetooth | ||||||||
| GQ GMC-300E +V4[36] | AA | LCD with backlight | Yes | No | One Geiger–Müller tube | 328 | 32.8 | 1 — 60 | Combined | USB | |||||
| GQ GMC-320 +V4[36] | AA | LCD with backlight | Yes | No | One Geiger–Müller tube | 328 | 32.8 | 1 – 60 | Combined | USB | gyroscope, temperature sensor | ||||
| GQ GMC-320 +V5[36] | AA | LCD with backlight | Yes | No | One Geiger–Müller tube | 328 | 32.8 | 1 – 60 | Combined | USB | WiFi, logging to a server, gyroscope, temperature sensor | ||||
| GQ GMC-300S[36] | 48x48px | AA | LCD with backlight | Yes | No | One Geiger–Müller tube | 1000 | 100 | 1 – 60 | Combined | USB | ||||
| GQ GMC-320S[36] | AA | LCD with backlight | Yes | No | One Geiger–Müller tube | 1000 | 100 | 1 – 60 | Combined | USB | gyroscope, temperature sensor | ||||
| GQ GMC-SE[36] | AA | LCD with backlight | Yes | No | One Geiger–Müller tube | 2000 | 200 | 1 – 60 | Combined | USB | |||||
| GQ GMC-500[36] | 18650 | LCD with backlight | Yes | No | One Geiger–Müller tube | 5000 | 500 | 1 – 60 | Combined | USB | WiFi, logging to a server, gyroscope | ||||
| GQ GMC-500+[36] | 48x64px | 135x78x25 | 18650 | LCD with backlight | Yes | No | Two Geiger–Müller tubes | 0 – 42.5e3 | 0 – 4.25e6 | 1 – 60 | Combined | USB | WiFi, logging to a server, gyroscope | ||
| GQ GMC-800[36] | AA | LCD with backlight | Yes | No | One Geiger–Müller tube | 2000 | 200 | 1 – 60 | Combined | USB | |||||
| GQ GMC-600[36] | 18650 | LCD with backlight | Yes | No | SBT-11 | 4250 | 425 | 1 – 60 | Combined | USB | WiFi, logging to a server, gyroscope | ||||
| GQ GMC-600+[36] | 18650 | LCD with backlight | Yes | No | LND 7317 | 10e3 | 1000 | 1 – 60 | Combined | USB | WiFi, logging to a server, gyroscope | ||||
| GQ GMC-510[36] | 18650 | LCD with backlight | Yes | No | M4011 | 4250 | 425 | 1 – 60 | Combined | USB | WiFi, logging to a server, gyroscope | ||||
| GQ GMC-520[36] | 18650 | LCD with backlight | Yes | No | M4011 | 4250 | 425 | 1 – 60 | Combined | USB | WiFi, logging to a server, gyroscope | ||||
| GQ GMC-520+[36] | 18650 | LCD with backlight | Yes | No | M4011 | 4250 | 425 | 1 – 60 | Combined | USB | WiFi, logging to a server, gyroscope | ||||
| Radex RD1503, RD1503+[25][24] | 48x64px | 105х60х26 | 90 | One or two AAA | LCD with backlight | Yes | Only RD1503+ | Geiger–Müller tube | 0.05 – 10 | 5 – 1000 | up to 40 | Combined, 0.1–1,25 MeV | No | ||
| Radex RD1706[24] | 48x64px | 105х60х26 | 90 | One or two AAA | LCD with backlight | Yes | Yes | Two Geiger–Müller tubes | 0.05 –1000 | 5 – 10e5 | 1 – 26 | Combined, 0.1–1.25 MeV | No | Background mode | |
| Radex RD1212[24] | 97x68x24 | 80 | One or two AAA | LCD with backlight | Yes | Yes | One Geiger–Müller tube | 0.05 – 999 | 5 – 10e5 | 1 – 10 | Combined, 0.4–3.5 MeV | USB | Background mode, integrated flashlight, time and date functions, multilingual | ||
| Radex RD1008[24] | 48x64px | 140х64х26 | 175 | AA | LCD with backlight | Yes | Yes | Two Geiger–Müller tubes | 0.1 – 1000 | 2 – 120 | 2 – 21 | Separated, 0.05–3.5 MeV | No | Background mode, separated indication of beta and gamma radiation | |
| RadiaCode 102[37][38][39] | 80x80px | Template:Country data Republic of Cyprus | conflicting answers (124x35x20 or 123x34x18) | 65 | built-in Lithium polymer battery | LCD with backlight | Yes | CsI(Tl) scintillator | 0.01 – 1000 | 1 — 10e5 | 0.5 | yes | USB and Bluetooth | thermometer, clock | |
| RadiaCode 103[37][38][40] | Template:Country data Republic of Cyprus | conflicting answers (124x35x20 or 123x34x18) | 65 | built-in Lithium polymer battery | LCD with backlight | Yes | CsI(Tl) scintillator | 0.01 – 1000 | 1 — 10e5 | 0.5 | yes | USB and Bluetooth | thermometer, clock | ||
| RadiaCode 103G[37][38][41] | Template:Country data Republic of Cyprus | conflicting answers (124x35x20 or 123x34x18) | 70 | built-in Lithium polymer battery | LCD with backlight | Yes | GAGG(Ce) Scintillator | 0.01 – 1000 | 1 — 10e5 | 0.5 | yes | USB and Bluetooth | thermometer, clock | ||
| RadTarge II D300[42] | 69x46x17 | 60 | Built-in lithium ion battery | LCD with backlight | Yes | Yes | YSO scintillator + SiPM | 0.5 – 5000 | 50 – 5e5 | < 8 | No, 0.03–1.5 MeV | USB | Dose equivalent rate + accumulated dose meter, pager-like clip, time and date functions, data logging and export (via Mac/PC software) | ||
| RadTarge II D700[43] | 69x46x17 | 60 | Built-in lithium-ion battery | LCD with backlight | Yes | Yes | YSO scintillator + SiPM | 0.01 — 1000 | 1 — 10e5 | < 2 | No, 0.02–3 MeV | USB | Dose equivalent rate + accumulated dose meter, pager-like clip, time and date functions, data logging and export (via Mac/PC software) | ||
| RadTarge II D900[44] | 69x46x17 | 60 | Built-in lithium-ion battery | LCD with backlight | Yes | Yes | YSO scintillator + SiPM | 0.1 – 10e5 | 10 – 10e7 | < 6 | No, 0.02–3 MeV | USB | Dose equivalent rate + accumulated dose meter, pager-like clip, time and date functions, data logging and export (via Mac/PC software) | ||
| RKSB-104[24] | 154х77х39 | 350 | 1 Nine-volt battery | LCD | No | No | Two Geiger–Müller tubes | 0.1 — 100 | 10 — 2e4 | 18 – 400 | Combined, 0.5–3.0 MeV | No | |||
| RKS-107[24] | 154x77x39 | 350 | 1 Nine-volt battery | LCD | No | No | Geiger–Müller tube | 0.1 — 99.99 | 10 — 9999 | ||||||
| Pripyat RKS-20.03[45][25] | Two SBM-20 Geiger–Müller tubes | ||||||||||||||
| DKG-RM1610[24] | 58х58х18 | 70 | Built-in accumulator | LCD | Yes | Yes | One Geiger–Müller tube | 0.01 — 1.2e6 | 1 — 1.2e8 | No | USB | Shock protection | |||
| EcotestCARD[lower-alpha 4] [25][24] | 80 | CR2450 | LCD | Yes | No | Semiconductor | 0.1–10e6 | 10–10e8 | Infrared | ||||||
| SOEKS 01M[25] | Geiger–Müller tube |
Notes
References
- ↑ "Electronic Dosimeter PM1211". https://radmetron.com/en/product/x-ray-and-gamma-radiation-dosimeters/electronic-dosimeters/electronic-dosimeter-pm1211.
- ↑ "Electronic Personal Dosimeter PM1300". https://radmetron.com/en/product/x-ray-and-gamma-radiation-dosimeters/personal-dosimeters/electronic-personal-dosimeter-pm1300.
- ↑ "Electronic Personal Dosimeter PM1300GN". https://radmetron.com/en/product/x-ray-and-gamma-radiation-dosimeters/personal-dosimeters/dozimetr-individualnyy-dkg-rm1300gn/#char.
- ↑ "Personal Radiation Detector PM1401GNM". https://radmetron.com/en/product/personal-radiation-detectors/prd-gamma-neutron/personal-radiation-detector-pm1401k-01m/.
- ↑ "Gamma Personal Radiation Detector PM1401MA". https://radmetron.com/en/product/personal-radiation-detectors/prd-gamma/gamma-personal-radiation-detector-pm1401ma.
- ↑ 6.0 6.1 "Multipurpose Hand-Held Radiation Monitor/Identifier PM1401K-3". https://radmetron.com/en/product/radionuclide-identification-devices/multipurpose-hand-held-radiation-monitor-identifier-pm1401k-3.
- ↑ "Survey meter PM1405P". https://radmetron.com/en/product/contamination-measurement-monitors/dozimetr-radiometr-mks-rm1405r.
- ↑ "Wrist Gamma Dosimeter РМ1603A". https://radmetron.com/en/product/x-ray-and-gamma-radiation-dosimeters/electronic-dosimeters/wrist-gamma-dosimeter-rm1603a.
- ↑ "Wrist Gamma Dosimeter РМ1603B". https://radmetron.com/en/product/x-ray-and-gamma-radiation-dosimeters/electronic-dosimeters/wrist-gamma-dosimeter-rm1603b.
- ↑ 10.0 10.1 "X-ray and Gamma Radiation Personal Dosimeter РМ1611". https://radmetron.com/en/product/x-ray-and-gamma-radiation-dosimeters/personal-dosimeters/x-ray-and-gamma-radiation-personal-dosimeter-pm1611/.
- ↑ "X-ray and Gamma Radiation Personal Dosimeter РМ1621". https://radmetron.com/en/product/x-ray-and-gamma-radiation-dosimeters/personal-dosimeters/x-ray-and-gamma-radiation-personal-dosimeter-rm1621/.
- ↑ "X-ray and Gamma Radiation Personal Dosimeter РМ1621A". https://radmetron.com/en/product/x-ray-and-gamma-radiation-dosimeters/personal-dosimeters/x-ray-and-gamma-radiation-personal-dosimeter-rm1621a.
- ↑ "X-ray and Gamma Radiation Personal Dosimeter РМ1621M". https://radmetron.com/en/product/x-ray-and-gamma-radiation-dosimeters/personal-dosimeters/x-ray-and-gamma-radiation-personal-dosimeter-rm1621m/#char.
- ↑ "X-ray and Gamma Radiation Personal Dosimeter РМ1621MA". https://radmetron.com/en/product/x-ray-and-gamma-radiation-dosimeters/personal-dosimeters/x-ray-and-gamma-radiation-personal-dosimeter-rm1621ma/.
- ↑ "Model 23: mrem Electronic Personal Dosimeter". https://ludlums.com/products/all-products/product/model-23.
- ↑ "Model 23-1 mSv Electronic Personal Dosimeter - Ludlum Measurements Inc.". https://ludlums.com/products/all-products/product/model-23-1.
- ↑ "Model K8 NUKE Safeguard Personal Radiation Indicator - Ludlum Measurements Inc.". https://ludlums.com/products/all-products/product/model-k8.
- ↑ 18.0 18.1 18.2 18.3 "Model 25 Series: Personal Radiation Monitor". https://ludlums.com/images/data_sheets/M25-series.pdf.
- ↑ 19.0 19.1 19.2 19.3 "LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER'S MANUAL". 2014. https://ludlums.com/images/product_manuals/M25_&_M25-1.pdf.
- ↑ 20.0 20.1 "Model 25 Series". https://ludlums.com/products/all-products/product/model-25-series.
- ↑ 21.0 21.1 "Model 25-IS Series". https://ludlums.com/products/all-products/product/model-25-is-series.
- ↑ "FNIRSI® GC-01 Nuclear Radiation Detector". https://www.fnirsi.com/products/gc-01.
- ↑ "FNIRSI® GC-02 Geiger Counter Nuclear Radiation Detector" (in en). https://www.fnirsi.com/products/gc-02.
- ↑ 24.00 24.01 24.02 24.03 24.04 24.05 24.06 24.07 24.08 24.09 24.10 Imported from Russian Wikipedia: Индивидуальные дозиметры
- ↑ 25.0 25.1 25.2 25.3 25.4 Imported from Ukrainian Wikipedia: Порівняння дозиметрів і радіометрів
- ↑ Allimann.com
- ↑ Дозиметр-радиометр АНРИ-01-02 "Сосна"
- ↑ 28.0 28.1 "Features - bGeigieZen" (in en-US). 2022-02-24. https://bgeigiezen.safecast.jp/features/.
- ↑ "Specifications" (in en). https://github.com/Safecast/bGeigieNanoKit/wiki/Specifications.
- ↑ 30.0 30.1 "bGeigieZen Assembled" (in en-US). 2023-07-21. https://bgeigiezen.safecast.jp/store-2/bgeigiezen-assembled/.
- ↑ Polimaster DKG-RM1203M or find a current model at Polimaster Ltd.
- ↑ "DKG-21M: Personal Gamma Radiation Dosimeter". https://ecotestgroup.com/products/dkg-21m/.
- ↑ "PRD GUARDER: Personal radiation dosimeter DKG-24". https://ecotestgroup.com/products/prd-guarder/.
- ↑ "TERRA with Bluetooth channel: Dosimeter-Radiometer МКS-05". https://ecotestgroup.com/products/terra-with-bluetooth-channel.
- ↑ "MKS-UM: Multipurpose Dosimeter-Radiometer". https://ecotestgroup.com/products/mks-um.
- ↑ 36.00 36.01 36.02 36.03 36.04 36.05 36.06 36.07 36.08 36.09 36.10 36.11 36.12 36.13 "GQ Geiger Counter Selection Guide". GQ Electronics LLC. https://www.gqelectronicsllc.com/support/GMC_Selection_Guide.htm. Retrieved 2022-10-06.
- ↑ 37.0 37.1 37.2 "Radiacode 1ox series" (in en-US). https://www.radiacode.com/.
- ↑ 38.0 38.1 38.2 Kolotukhin, Igor. "Quick Guide Manual" (in en-US). Radiacode. https://coda.io/d/radiacode-cyberspace_dTtFtorf-v-/Quick-Guide-Manual_suS3AbP_#_lu5Ub3i4.
- ↑ "Detector of nuclear radiation and spectrometer Radiacode 102: SKU RC102" (in en-US). https://www.radiacode.com/products#!/Detector-of-nuclear-radiation-and-spectrometer-Radiacode-102/p/601830018.
- ↑ "Detector of nuclear radiation and spectrometer Radiacode 103G: SKU RC103" (in en-US). https://www.radiacode.com/products#!/Detector-of-nuclear-radiation-and-spectrometer-Radiacode-103/p/602724693.
- ↑ "Detector of nuclear radiation and spectrometer Radiacode 103G: SKU RC103G" (in en-US). https://www.radiacode.com/products#!/Detector-of-nuclear-radiation-and-spectrometer-Radiacode-103G/p/640576121.
- ↑ "Electronic Personal Dosimeter | RadTarge II D300 | X-Z LAB" (in en-US). X-Z LAB. https://www.x-zlab.com/product/radtargeii-d300-electronic-personal-dosimeter/.
- ↑ "Electronic Personal Dosimeter | RadTarge II D700 | X-Z LAB" (in en-US). X-Z LAB. https://www.x-zlab.com/product/radtargeii-d700-electronic-personal-dosimeter/.
- ↑ "Electronic Personal Dosimeter | RadTarge II D900 | X-Z LAB" (in en-US). X-Z LAB. https://www.x-zlab.com/product/radtargeii-d900-electronic-personal-dosimeter/.
- ↑ "Rukovodstvo po ekspluatatsii radiometra RKS-20.03 "Pripyat"". https://sorbpolimer.com.ua/uploads/rks-20_03-manual.pdf.
Literature
- "Intercomparison of personal dose equivalent measurements by active personal dosimeters". International Atomic Energy Agency. Chicago. 2007. https://www-pub.iaea.org/MTCD/Publications/PDF/te_1564_web.pdf.
- "Evaluation of the calibration procedure of active personal dosemeters for interventional radiology". Radiation Protection Dosimetry 131 (1): 87–92. 2008. doi:10.1093/rpd/ncn225. PMID 18757898.
- "Comparison of Personal Dosimeters". Radiation Emergency Medical Management (REMM). United States Department of Health and Human Services. https://remm.hhs.gov/dosimeter_marketsurvey.htm. Retrieved October 10, 2022.