Medicine:Fractional flow reserve

From HandWiki

Fractional flow reserve (FFR) is a diagnostic technique used in coronary catheterization. FFR measures pressure differences across a coronary artery stenosis (narrowing, usually due to atherosclerosis) to determine the likelihood that the stenosis impedes oxygen delivery to the heart muscle (myocardial ischemia).[1] Fractional flow reserve is defined as the pressure after (distal to) a stenosis relative to the pressure before the stenosis.[2] The result is an absolute number; an FFR of 0.80 means that a given stenosis causes a 20% drop in blood pressure. In other words, FFR expresses the maximal flow down a vessel in the presence of a stenosis compared to the maximal flow in the hypothetical absence of the stenosis.

Procedure

During coronary catheterization, a catheter is inserted into the femoral (groin) or radial arteries (wrist) using a sheath and guidewire. FFR uses a small sensor on the tip of the wire (commonly a transducer) to measure pressure, temperature and flow to determine the exact severity of the lesion. This is done during maximal blood flow (hyperemia), which can be induced by injecting products such as adenosine or papaverine. A pullback of the pressure wire is performed, and pressures are recorded across the vessel.[3]

When interpreting FFR measurements, higher values indicate a non-significant stenosis, whereas lower values indicate a significant lesion. There is no absolute cut-off point at which an FFR measurement is considered abnormal. However, reviews of clinical trials show a cut-off range between 0.75 and 0.80 has been used when determining significance.[4]

Equation

Fractional flow reserve (FFR) is the ratio of maximum blood flow distal to a stenotic lesion to normal maximum flow in the same vessel. It is calculated using the pressure ratio

[math]\displaystyle{ FFR = \frac{p_d}{p_a} }[/math]

where [math]\displaystyle{ p_d }[/math] is the pressure distal to the lesion, and [math]\displaystyle{ p_a }[/math] is the pressure proximal to the lesion.

Rationale

The decision to perform a percutaneous coronary intervention (PCI) is usually based on angiographic results alone. Angiography can be used for the visual evaluation of the inner diameter of a vessel. In ischemic heart disease, deciding which narrowing is the culprit lesion is not always clear-cut. Fractional flow reserve can provide a functional evaluation by measuring the pressure decline caused by a vessel narrowing.[4]

Advantages and disadvantages

FFR has certain advantages over other techniques to evaluate narrowed coronary arteries, such as coronary angiography, intravascular ultrasound or CT coronary angiography. For example, FFR takes into account collateral flow, which can render an anatomical blockage functionally unimportant. Also, standard angiography can underestimate or overestimate narrowing, because it only visualizes contrast inside a vessel.[5] Finally, when compared to other indices of vessel narrowing, FFR seems to be less vulnerable to variability between patients.[6]

Other techniques can also provide information which FFR cannot. Intravascular ultrasound, for example, can provide information on plaque vulnerability, whereas FFR measures are only determined by plaque thickness. There are newly developed technologies that can assess both plaque vulnerability and FFR from CT by measuring the vasodilitative capacity of the arterial wall. [citation needed]

FFR allows real-time estimation of the effects of a narrowed vessel, and allows for simultaneous treatment with balloon dilatation and stenting. On the other hand, FFR is an invasive procedure for which non-invasive (less drastic) alternatives exist, such as cardiac stress testing. In this test, physical exercise or intravenous medication (adenosine/dobutamine) is used to increase the workload and oxygen demand of the heart muscle, and ischemia is detected using ECG changes or nuclear imaging.

DEFER study

In the DEFER study, fractional flow reserve was used to determine the need for stenting in patients with intermediate single vessel disease. In stenosis patients with an FFR of less than 0.75, outcomes were significantly worse. In patients with an FFR of 0.75 or more however, stenting did not influence outcomes.[7]

FAME study

The Fractional Flow Reserve versus Angiography for Multivessel Evaluation (FAME) study evaluated the role of FFR in patients with multivessel coronary artery disease.[8] In 20 centers in Europe and the United States, 1005 patients undergoing percutaneous coronary intervention with drug eluting stent implantation were randomized to intervention based on angiography or based on fractional flow reserve in addition to angiography. In the angiography arm of the study, all suspicious-looking lesions were stented. In the FFR arm, only angiographically suspicious lesions with an FFR of 0.80 or less were stented.[citation needed]

In the patients whose care was guided by FFR, fewer stents were used (2.7±1.2 and 1.9±1.3, respectively). After one year, the primary endpoint of death, nonfatal myocardial infarction, and repeat revascularization were lower in the FFR group (13.2% versus 18.3%), largely attributable to fewer stenting procedures and their associated complications. There also was a non-significant higher number of patients with residual angina (81% versus 78%). In the FFR group, hospital stay was slightly shorter (3.4 vs 3.7 days) and procedural costs were less ($5,332 vs $6,007). FFR did not prolong procedure (around 70 minutes in both groups).

References

  1. "Measurement of fractional flow reserve to assess the functional severity of coronary-artery stenoses". N. Engl. J. Med. 334 (26): 1703–8. June 1996. doi:10.1056/NEJM199606273342604. PMID 8637515. 
  2. Hwang, Doyeon; Lee, Joo Myung; Koo, Bon-Kwon (2016). "Physiologic Assessment of Coronary Artery Disease: Focus on Fractional Flow Reserve". Korean Journal of Radiology (The Korean Society of Radiology) 17 (3): 307–320. doi:10.3348/kjr.2016.17.3.307. ISSN 1229-6929. PMID 27134520. 
  3. Chowdhury, Mohsin; Osborn, Eric A. (2020). "Physiological Assessment of Coronary Lesions in 2020". Current Treatment Options in Cardiovascular Medicine 22 (1): 2. doi:10.1007/s11936-020-0803-7. ISSN 1092-8464. PMID 31938934. 
  4. 4.0 4.1 Achenbach, Stephan; Rudolph, Tanja; Rieber, Johannes; Eggebrecht, Holger; Richardt, Gert; Schmitz, Thomas; Werner, Nikos; Boenner, Florian et al. (2017). "Performing and Interpreting Fractional Flow Reserve Measurements in Clinical Practice: An Expert Consensus Document". Interventional Cardiology Review (Radcliffe Group Ltd) 12 (2): 97–109. doi:10.15420/icr.2017:13:2. ISSN 1756-1477. PMID 29588737. 
  5. Pijls, N H; van Son, J A; Kirkeeide, R L; De Bruyne, B; De Gould, K L (April 1993). "Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenosis severity before and after percutaneous transluminal coronary angioplasty". Circulation 87 (4): 1354–1367. doi:10.1161/01.CIR.87.4.1354. PMID 8462157. 
  6. Algranati, Dotan; Kassab, Ghassan S.; Lanir, Yoram (May 2013). "Flow Restoration Post Revascularization Predicted by Stenosis Indices: Sensitivity to Hemodynamic Variability". Am J Physiol Heart Circ Physiol 305 (2): H145-54. doi:10.1152/ajpheart.00061.2012. PMID 23645461. https://journals.physiology.org/doi/pdf/10.1152/ajpheart.00061.2012. Retrieved 5 May 2021. 
  7. "Percutaneous coronary intervention of functionally nonsignificant stenosis: 5-year follow-up of the DEFER Study". J. Am. Coll. Cardiol. 49 (21): 2105–11. May 2007. doi:10.1016/j.jacc.2007.01.087. PMID 17531660. 
  8. "Fractional flow reserve versus angiography for guiding percutaneous coronary intervention". N. Engl. J. Med. 360 (3): 213–24. January 2009. doi:10.1056/NEJMoa0807611. PMID 19144937.