Chemistry:Polyhydroxyethylmethacrylate

From HandWiki
Revision as of 10:56, 26 June 2023 by Steve Marsio (talk | contribs) (over-write)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Polyhydroxyethylmethacrylate
Polyhydroxyethylmethacrylate structural.svg
Names
IUPAC name
Poly(2-hydroxyethyl methacrylate)
Other names
PHEMA, poly-HEMA, Hydron
Identifiers
ChemSpider
  • None
Properties
(C6H10O3)n
Molar mass Variable
Except where otherwise noted, data are given for materials in their standard state (at 25 °C [77 °F], 100 kPa).
Infobox references
Tracking categories (test):

Poly(2-hydroxyethyl methacrylate) (pHEMA) is a polymer that forms a hydrogel in water. Poly (hydroxyethyl methacrylate) (PHEMA) hydrogel for intraocular lens (IOL) materials was synthesized by solution polymerization using 2-hydroxyethyl methacrylate (HEMA) as raw material, ammonium persulfate and sodium pyrosulfite (APS/SMBS) as catalyst, and triethyleneglycol dimethacrylate (TEGDMA) as cross-linking additive. It was invented by Drahoslav Lim and Otto Wichterle for biological use.[1] Together they succeeded in preparing a cross-linking gel which absorbed up to 40% of water, exhibited suitable mechanical properties and was transparent. They patented this material in 1953.

Applications

Contact lenses

In 1959, this material was first used as an optical implant. Wichterle thought pHEMA might be a suitable material for a contact lens and gained his first patent for soft contact lenses.[2] By late 1961, he succeeded in producing the first four pHEMA hydrogel contact lenses on a home-made apparatus.

Copolymers of pHEMA are still widely used today. Poly-HEMA functions as a hydrogel by rotating around its central carbon. In air, the non-polar methyl side turns outward, making the material brittle and easy to grind into the correct lens shape. In water, the polar hydroxyethyl side turns outward and the material becomes flexible. Pure pHEMA yields lenses that are too thick for sufficient oxygen to diffuse through, so all contact lenses that are pHEMA based are manufactured with copolymers that make the gel thinner and increase its water of hydration.[3] These copolymer hydrogel lenses are often suffixed "-filcon", such as Methafilcon, which is a copolymer of hydroxyethyl methacrylate and methyl methacrylate. Another copolymer hydrogel lens, called Polymacon, is a copolymer of hydroxyethyl methacrylate and ethylene glycol dimethacrylate.

Cell culture

pHEMA is commonly used to coat cell culture flasks in order to prevent cell adhesion and induce spheroid formation, particularly in cancer research. Older alternatives to pHEMA include agar and agarose gels.[4][5]

References

  1. Wichterle, O.; Lím, D. (1960). "Hydrophilic Gels for Biological Use". Nature 185 (4706): 117–8. doi:10.1038/185117a0. Bibcode1960Natur.185..117W. 
  2. Kyle, Robert A.; Steensma, David P.; Shampo, Marc A. (2016-03-01). "Otto Wichterle—Inventor of the First Soft Contact Lenses" (in English). Mayo Clinic Proceedings 91 (3): e45–e46. doi:10.1016/j.mayocp.2016.01.016. ISSN 0025-6196. PMID 26944252. https://www.mayoclinicproceedings.org/article/S0025-6196(16)00071-9/fulltext. 
  3. Ratner, Buddy D. (2004). Biomaterials Science, An Introduction to Materials in Medicine. Elsevier Academic Press. ISBN 0-12-582463-7. [page needed]
  4. Katt, Moriah E.; Placone, Amanda L.; Wong, Andrew D.; Xu, Zinnia S.; Searson, Peter C. (12 February 2016). "In Vitro Tumor Models: Advantages, Disadvantages, Variables, and Selecting the Right Platform". Frontiers in Bioengineering and Biotechnology 4: 12. doi:10.3389/fbioe.2016.00012. PMID 26904541. 
  5. Friedrich, Juergen; Seidel, Claudia; Ebner, Reinhard; Kunz-Schughart, Leoni A (12 February 2009). "Spheroid-based drug screen: considerations and practical approach". Nature Protocols 4 (3): 309–324. doi:10.1038/nprot.2008.226. PMID 19214182.