Chemistry:1,2-Dichlorotetrafluoroethane
| |||
Names | |||
---|---|---|---|
Preferred IUPAC name
1,2-Dichloro-1,1,2,2-tetrafluoroethane | |||
Other names
R-114, CFC-114, halon 242, cryofluorane, Freon 114, Genetron 114, Refrigerant 114
| |||
Identifiers | |||
3D model (JSmol)
|
|||
ChEMBL | |||
ChemSpider | |||
EC Number |
| ||
PubChem CID
|
|||
RTECS number |
| ||
UNII | |||
UN number | 1958 | ||
| |||
| |||
Properties | |||
C2Cl2F4 | |||
Molar mass | 170.92 g/mol | ||
Appearance | colorless gas[1] | ||
Odor | faint, ether-like (high concentrations)[1] | ||
Density | 1.455 g/cm3 | ||
Melting point | −94 °C (−137 °F; 179 K) | ||
Boiling point | 3.5 °C (38.3 °F; 276.6 K) | ||
0.01%[1] | |||
Vapor pressure | 1.9 atm (21°C)[1] | ||
Hazards | |||
Main hazards | Ozone depletor | ||
GHS pictograms | |||
GHS Signal word | Warning | ||
H280, H420 | |||
P410+403, P502 | |||
Flash point | nonflammable [1] | ||
Lethal dose or concentration (LD, LC): | |||
LC50 (median concentration)
|
720,000 ppm (rat, 30 min) 700,000 ppm (mouse, 30 min) 750,000 ppm (rabbit, 30 min)[2] | ||
NIOSH (US health exposure limits): | |||
PEL (Permissible)
|
TWA 1000 ppm (7000 mg/m3)[1] | ||
REL (Recommended)
|
TWA 1000 ppm (7000 mg/m3)[1] | ||
IDLH (Immediate danger)
|
15000 ppm[1] | ||
Except where otherwise noted, data are given for materials in their standard state (at 25 °C [77 °F], 100 kPa). | |||
verify (what is ?) | |||
Infobox references | |||
1,2-Dichlorotetrafluoroethane, or R-114, also known as cryofluorane (INN), is a chlorofluorocarbon (CFC) with the molecular formula ClF2CCF2Cl. Its primary use has been as a refrigerant. It is a non-flammable gas with a sweetish, chloroform-like odor with the critical point occurring at 145.6 °C and 3.26 MPa. When pressurized or cooled, it is a colorless liquid. It is listed on the Intergovernmental Panel on Climate Change's list of ozone depleting chemicals, and is classified as a Montreal Protocol Class I, group 1 ozone depleting substance.[3]
When used as a refrigerant, R-114 is classified as a medium pressure refrigerant.
The U.S. Navy uses R-114 in its centrifugal chillers in preference to R-11 to avoid air and moisture leakage into the system. While the evaporator of an R-11 charged chiller runs at a vacuum during operation, R-114 yields approximately 0 psig operating pressure in the evaporator.
Manufactured and sold R-114 was usually mixed with the non symmetrical isomer 1,1-dichlorotetrafluoroethane (CFC-114a), as separation of the two isomers is difficult.[4]
Dangers
Aside from its immense environmental impacts, R114, like most chlorofluoroalkanes, forms phosgene gas when exposed to a naked flame.[5]
References
- ↑ 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 NIOSH Pocket Guide to Chemical Hazards. "#0201". National Institute for Occupational Safety and Health (NIOSH). https://www.cdc.gov/niosh/npg/npgd0201.html.
- ↑ "Dichlorotetrafluoroethane". Immediately Dangerous to Life and Health Concentrations (IDLH). National Institute for Occupational Safety and Health (NIOSH). https://www.cdc.gov/niosh/idlh/76142.html.
- ↑ "Ozone-Depleting Substances". 17 July 2015. https://www.epa.gov/ozone-layer-protection/ozone-depleting-substances.
- ↑ Laube, Johannes C.; Mohd Hanif, Norfazrin; Martinerie, Patricia; Gallacher, Eileen; Fraser, Paul J.; Langenfelds, Ray; Brenninkmeijer, Carl A. M.; Schwander, Jakob et al. (9 December 2016). "Tropospheric observations of CFC-114 and CFC-114a with a focus on long-term trends and emissions". Atmospheric Chemistry and Physics 16 (23): 15347–15358. doi:10.5194/acp-16-15347-2016. Bibcode: 2016ACP....1615347L.
- ↑ "False Alarms: The Legacy of Phosgene Gas". 4 January 2021. https://hvacrschool.com/phosgene-gas/.
External links
- Material Safety Data Sheet from Honeywell International Inc., dated 22 August 2007.
- CDC - NIOSH Pocket Guide to Chemical Hazards
Original source: https://en.wikipedia.org/wiki/1,2-Dichlorotetrafluoroethane.
Read more |